Installing the System Piping
3.7.5 Wiring Diagram - Zone Valve System
The NCB-H Boilers can operate a heating system with up to 3 zones. The following is the wiring diagram for a
zone valve system with 3 zones.
Without 24VAC connections
N
A/
H
DH
W
PR
I
L
N
L
N
L
N
L
N
L
Z3
Z2
Z1
SUPPLY
TEMPERATURE SENSOR
RETURN
OUTDOOR
T/S_ZONE3
R
W
C
T/S_ZONE2
R
W
C
T/S_ZONE1
R
W
C
AC24VN
AC24VL
lLWCO
R
W
C
T/
S_Reci
r
COM
NO
NC
ZO
N
E_V/V
3
COM
NO
NC
ZO
N
E_V/V
2
COM
NO
NC
ZO
N
E_V/V
1
SUPPLY
TEMPERATURE SENSOR
RETURN
OUTDOOR
T/S_ZONE3
R
W
C
T/S_ZONE2
R
W
C
T/S_ZONE1
R
W
C
AC24VN
AC24VL
lLWCO
R
W
C
T/S_Recir
COM
NO
NC
ZONE_V/V3
COM
NO
NC
ZONE_V/V2
COM
NO
NC
ZONE_V/V1
Thermostat 3
Thermostat 2
Thermostat 1
N
A/H
DHW
PRI
L
N
L
N
L
N
L
N
L
Z3
Z2
Z1
System pump
(max. 2.5 A)
Recirculation pump
(max. 2.5 A)
Recirculation Timer,
Aquastat,
or HotButton
Push Button
Pump Ground
Zone
valve 3
(max. 0.75 A)
Zone
valve 2
(max. 0.75 A)
Zone
valve 1
(max. 0.75 A)
Note
●
NO (Normal Open): Power is supplied when the zone valve is operating, and power turns off when
the zone valve stops.
●
NC (Normal Close): Power is supplied when the zone valve stops, and power turns off when the
zone valve is operating.
●
COM: 24 V AC COMMON