F5 HYDR UNIT
Model of electrohydraulic unit installed: SOL (with solenoids) – REV
(reversing). REV can be equal to 1, 2 and 3 respectively with correct units, fast
units and very fast units.
F6 ENERG SAVE
It activates or deactivates the energy saving on the control of the
electrohydraulic unit: it avoids the keeping of the motor running when it is not
necessary. It is particularly useful in small sailing vessels. ON activates it, OFF
deactivates it.
F7 RUDDER ALR
It activates or deactivates the signaling of an eventual alarm due to a delay of
the rudder actioning (signaled with ‘NO RUDDER ALARM’): ON activates it,
OFF deactivates it.
F8 COMP TYPE
Model of the connected magnetic compass: FG90 (FGX60/3, FGX90/3 or
FGX90N) – SC2 (Smart Compass SC2N or SC2G).
F9 COMP ALIGN
Alignment of the compass: it allows to increase or decrease the reading of the
electronic compass (FGX60/3 or FGX90) of a fixed quantity avoiding the
physical turning of it.
F10 CMP DAMPING
Damping filter on the compass (FGX60/3 or FGX90): the higher is the value
and the more filtered the compass is.
F11 INTEG TC
Time constant of the main integrating control: avoid changing it (only for
qualified technicians).
F12 DERIV TC
Time constant of the main derivation control: avoid changing it (only for
qualified technicians).
F13 NAV GAIN
Gain of the NAV control: avoid changing it (only for qualified technicians).
F14 NAV2 FUNCT
Selection of the function assigned to NAV2: NAV2 (navigation with the second
chart-plotter), WIND (navigation with wind direction sensor) or OFF (disabled).
F15 COURSE TMR
Off-course timeout alarm: the timeout (in seconds) between an off-course (set
course and heading differ of 20 degrees at least) and the start of the OFF-
COURSE alarm.