INTEJAN (HOT WATER) CIRCULATOR

USER

 

INSTRUCTIONS

Publication No. ZZ 1092/1

August 2000

THIS APPLIANCE MUST BE EARTHED

IMPORTANT: IT IS A STATUTORY REQUIREMENT THAT ALL GAS APPLIANCES BE INSTALLED BY COMPETENT
PERSONS, (i.e. CORGI REGISTERED INSTALLERS) IN ACCORDANCE WITH THE GAS SAFETY
(INSTALLATION AND USE) REGULATIONS (CURRENT EDITION). FAILURE TO COMPLY WITH THESE
REGULATIONS MAY RESULT IN PROSECUTION.

1.

TO LIGHT YOUR CIRCULATOR

1.1

Ensure that the gas and water supplies to the heater are
turned on.

1.2

Set both the “AIR HEATER” and “WATER HEATER”
switches on the time control to the “OFF” position.

1.3

Set the thermostat (see para. 3).

1.4

Switch on the electrical supply to the heater.

1.5

Set the “WATER HEATER” switch on the time control
to “CONT” After a period of 15-20 seconds the burner
will ignite automatically, indicated by the green LED
light marked ‘

ON

’ on the indicator panel (see Fig. 2).

1.6

The water heater will now operate automatically under
thermostatic control.

1.7

If the burner does not ignite the first time, the red LED

light marked ‘

LOCKOUT

’ will light. If this should occur,

check that the gas supply to the appliance is turned on,
wait approximately 10 seconds and then press the
button marked ‘

RESET

’ to re-initiate the ignition

sequence.

1.8

If, after carrying out the above instructions several
times, the green light fails to remain lit, contact your
local service engineer.

2.

TO STOP YOUR CIRCULATOR

2.1

For short periods, e.g. weekends:

Turn the “WATER HEATER” switch to the “OFF”
position, this will cause the burner to extinguish. When
you require the circulator on again, turn to Water Heater
switch to the “ON” position.

MA X .

MI N .

1

2

1. Thermostat
2. Circulator

WARNING:

This appliance MUST be used in accordance with these
instructions. Failure to do so, may prove dangerous and may
also cause injury! You MUST take note of ALL warnings
detailed both in these instructions AND on the appliance.
UNDER NO CIRCUMSTANCES MUST ANY FACTORY
SEALED COMPONENTS BE INTERFERED WITH!

WHAT IS THE INTEJAN

CIRCULATOR?

Your Intejan Circulator is an integral hot water
heater designed to provide domestic hot
water. The water temperature is controlled by
a thermostat in the appliance. Whilst the
Circulator is integral, its operation is totally
independant of the Warm Air Heater, thereby
providing hot water during periods when the
Air Heater is not being used, or is being used
in air circulation mode.

Note:

The viewing port of the heater (and its surroundings) get VERY hot during use. Care MUST be taken to avoid contact which may
result in severe burn injury!