47
Nautilus® Commercial T9 Series Treadmill Service Manual
Is LED 4 lit on
Drive board?
Measure line voltage to
P1 and P6 (110V), P3
and P5 (230V) from
Configuration plate.
Is the
voltage
good?
Check fuses F1,
or F2 on Drive
assembly.
Are the fuses
good?
Replace the
Configuration
Plate Assembly.
Replace the blown
fuse.
Remove cable #41170
from the J1 on the Drive
board and check for
12VDC between pins 3
and 6.
Is the
voltage
good?
Replace the Drive
Board
Reattach #41170
to J1, remove the
console and
disconnect the
cables.
Check for 12VDC
between pins 3
and 6 on the cable
#41170.
Is the
voltage
good?
Replace the
Console board.
Replace the
#41170 main
cable.
End
There is no
Console display.
End
End
Replace the Drive
Board.
End
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
No Display / No Device
Operation
SECTION 3: T912 TROUBLESHOOTING ELECTRICAL PROBLEMS
Troubleshooting Flowchart: No Display / No Device Operation
Summary of Contents for Be Strong Commerical T912
Page 22: ...22 SECTION 2 CONSOLE CODES T9 14 16...
Page 66: ...66 SECTION 4 T914 916 TROUBLESHOOTING ELECTRICAL PROBLEMS...
Page 68: ...68 SECTION 4 T914 916TROUBLESHOOTING ELECTRICAL PROBLEMS...
Page 84: ...84 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 86: ...86 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 88: ...88 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 90: ...90 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 92: ...92 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 98: ...98 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 100: ...100 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 102: ...102 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 104: ...104 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 106: ...106 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 112: ...112 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 114: ...114 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 116: ...116 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 118: ...118 SECTION 6 PARTS LIST AND EXPLODED VIEWS...