Nautilus® Commercial T9 Series Treadmill Service Manual
Troubleshooting Flowchart: Non-Functional CHR
CHR does not
function.
Check for 2VDC
between the top
and bottom
contact plates on
each handgrip
Is the
voltage
good?
Remove the
contact plates from
handgrips and
recheck voltage.
End
Is the CHR
working?
End
No
Yes
No
Yes
Replace the
Controller/
Processor PCB.
Cycle the power.
Is the
voltage is
good?
Replace the CHR
PCB.
Replace the CHR,
making sure the
wire tabs do not
contact each other
inside the Ergo
Bar Assembly.
No
Yes
SECTION 4: T914/916 TROUBLESHOOTING ELECTRICAL PROBLEMS
NOTE: Before troubleshooting a non-functional CHR, verify the Contact HR mode is enabled in the
CUSTOMIZE Service Menu.
Summary of Contents for Be Strong Commerical T912
Page 22: ...22 SECTION 2 CONSOLE CODES T9 14 16...
Page 66: ...66 SECTION 4 T914 916 TROUBLESHOOTING ELECTRICAL PROBLEMS...
Page 68: ...68 SECTION 4 T914 916TROUBLESHOOTING ELECTRICAL PROBLEMS...
Page 84: ...84 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 86: ...86 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 88: ...88 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 90: ...90 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 92: ...92 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 98: ...98 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 100: ...100 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 102: ...102 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 104: ...104 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 106: ...106 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 112: ...112 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 114: ...114 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 116: ...116 SECTION 6 PARTS LIST AND EXPLODED VIEWS...
Page 118: ...118 SECTION 6 PARTS LIST AND EXPLODED VIEWS...