MoniMax 5600 6. Appendix
6 - 18
F. Cencon Lock
Initial Operating Instructions
Each lock is shipped from the factory in Shelved Mode, operating on a standard combination (50-25-
50). The “one time only” combination does not function when the lock is in this condition. The correct
opening procedure for a new lock is :
Turn the Dial left (CCW) until the letters “EC” (Enter Combination) appear on the LCD
Enter the factory combination of 50-25-50 by sequentially pressing those six buttons. The LCD will
display these number as they are entered.
When the combination has been correctly entered, the LCD will read :OPr” meaning “Open right.”
Turn the Dial right (CW) until it stops. The lock’s bolt is now retracted and the lock is open.
Turning the Dial left (CCW) will extend the lock’s bolt
Try this several times until you are comfortable with the operation of the lock.
Change Shelved Mode Combination
For System 2000 Locks with a code level of 71, or greater, you may change the Shelved Mode
combination. You may change the default Factory Combination of 50-25-50 to a new combination to
be used while the lock is still in Shelved Mode. Once you have changed the combination for the first
time, you may want to change the combination again to a different Shelved Mode combination. You
can even change it back to the Factory combination of 50-25-50
Required Items: Change Key, Current Shelved Mode Combination
Note: You can only change the Shelved Mode combination while operating in Shelved Mode. Once a
lock is “activated” in any mode, the Shelved Mode combination returns to the Factory Default of 50-25-
50
To change the Shelved Mode combination:
1. Power Lock -> EC
Turn the Dial to the left (CCW) until “EC” (Enter Combination) is displayed.
2. EC -> Enter Shelved Mode Combination -> OPr
Enter the current Shelved Mode combination (either 50-25-50 or a changed Shelved Mode
combination) by sequentially pressing those digits on the lock keypad. The numbers will be
displayed on the LCD as they are entered.
3. OPr -> Retract Bolt
Summary of Contents for MoniMax 5600
Page 1: ...MoniMax 5600 Operator Manual Copyright Nautilus Hyosung Inc 2009 All right reserved...
Page 5: ...MoniMax 5600 1 Introduction 1 1 Chapter 1 Introduction...
Page 9: ...MoniMax 5600 2 Safety Precautions 1 2 Chapter 2 Safety Precautions...
Page 12: ...MoniMax 5600 3 Hardware Specifications 3 1 Chapter 3 Hardware Specifications...
Page 29: ...MoniMax 5600 4 Operating Instructions 4 1 Chapter 4 Operating Instructions...
Page 55: ...MoniMax 5600 4 Operating Instructions 4 27 8 Lastly press the feed button...
Page 56: ...MoniMax 5600 5 Operator Function 5 1 Chapter 5 Operator Function...
Page 71: ...MoniMax 5600 6 Appendix 6 1 Chapter 6 Appendix...
Page 76: ...MoniMax 5600 6 Appendix 6 6 Bill with folded lines...
Page 86: ...MoniMax 5600 6 Appendix 6 16 Fig 6 5 Changing Battery 1...
Page 87: ...MoniMax 5600 6 Appendix 6 17 Fig 6 6 Changing Battery 2...
Page 126: ...MoniMax 5600 6 Appendix 6 56 Fig 6 9 Anchor diagram for MoniMax 5600 ATM...