GV60 TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
PAGE 4.1.34
VERSION 1.0 2018-01-01
RF Power Module Faults
There are many alarms on the AUI (local or remote) or controller UI, prefixed by the text
RF Module
,
that indicate faults related to one or more of the RF power modules. The number that appears after
RF Module
(1-24) identifies the position of the affected module. Numbers correspond to modules in a
left to right, top to bottom sequence, as viewed from the front of the transmitter.
1.
Check the forward power reading on the UI or AUI. If it is less than the preset level, one or more RF
power modules are defective. Proceed to
“RF Power Module Fault Validation” on page 4.1.36
2.
If the forward power reading in
is normal, go to the controller UI’s
Alarms
screen or select
the AUI’s (local or remote)
Status
button on the remote AUI to check for other alarms that may
have triggered the RF power module alarm.
3.
From the remote AUI’s
Meter List View
), click the
i
(information) button
next to the RF Modules # folder in the Transmitter Layout section to view the status screen for all
modules or click the right-hand arrow to expand the RF Modules folder to allow clicking on the
i
button for an individual RF Module (e.g., RF Module 1, see
displays critical parameters for all 24 RF power modules. As an aid in troubleshooting, compare
parameters to isolate possible module faults.
Figure 4.1.7: AUI - Meter List View page
1. Click here to open the
Meter List View page
2. Click here to open the
RF Module status screen
3. Click here to expand
folder to allow viewing of
each RF Module’s
status screen
Summary of Contents for GV60
Page 2: ......
Page 4: ......
Page 8: ...GV60 TROUBLESHOOTING MANUAL PAGE 4 VIII VERSION 1 0 2018 01 01 ...
Page 102: ...GV60 TROUBLESHOOTING MANUAL PARTS LISTS PAGE 4 2 12 VERSION 1 0 2018 01 01 ...
Page 463: ...VERSION 1 0 2018 01 01 MD 17 Figure MD 17 NAPA31C Power Amplifier PWB Q1 ...
Page 475: ...GV60 TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 4 6 2 VERSION 1 0 2018 01 01 ...
Page 476: ......