background image

Specifications

13

Ba ery Temperature Compensa on

High temperature
Low Temperature
Ba ery over-temperature protec on

Device Protec on

Reverse Polarity

Over Voltage
Over Current

Bad Ba ery Detect

-17mV per °C above 30°C

+17mV per °C below 21°C

60°C

Over Temperature

Charge Algorithm

Voltage

Diagnosis

Recovery

Bulk

Absorption

Analysis

Float

Current

Step

1

2

3

4

5

6

Voltage Range

MAIN BATT input
SOLAR PANEL input

Solar Regulator

Type
Output Current
Output Power 

12V Alternator Input

Turn ON
Turn OFF
Over-Voltage

24V Alternator Input

Turn ON
Turn OFF
Over-Voltage

Igni on Over-ride (12V / 24V)

Turn ON
Turn OFF
Over-Voltage

Ba ery charge output

Voltage
Max Current
Max Power
Opera ng Temperature
Standby Current (switch ON)
Dimensions 

Remote Display 

USB charge output (each port)

Ba ery Gauge display range

Ba ery Types

Bulk Voltage

Float Voltage

AGM / Gel

14.4V

13.6V

Standard Wet

14.6V

13.6V

Calcium

14.8V

13.6V

Lithium Ion

14.4V

13.6V

9V - 42V

11V - 32V

13.2V
12.6V

MPPT

375W

25A

14.8V - 16V

-20°C to 85°C

11.5V

23V

15.5V - 16V

31V - 32V

3V -14.8V

25A

375W

26.4V
23.2V

29.6V - 31V

12.0V

24.0V

257mm x 261mm x 120mm

Op onal

10.7V - 14.7V

5V-3A, 9V-2A, 12V-1.5A

< 35mA

Summary of Contents for DC25 Distribution Box

Page 1: ...DC25DistributionBox ...

Page 2: ......

Page 3: ... for Installation Safety Information Wiring Diagram Features Introduction Connecting Auxiliary battery Connecting Solar Panels Connecting External Battery Chargers Ignition Over ride System Operation Remote Monitor Remote Monitor Status Messages Specifications Warranty Selecting Battery Type ...

Page 4: ...up to 25A of current to the auxiliary battery using an optimized 6 stage charge algorithm to fridges and other small appliances These connectors can also be used with external battery chargers as an alternative to the built in dedicated charge port Heavy duty connectors can be used for connecting a variety of accessories from inverters 600W max The introduction of two dual port USB modules with fa...

Page 5: ...ain Switch 50A Heavy duty IN OUT connectors SOLAR PANEL input Remote Monitor port IGNITION sense port MAIN BATT input External Charger input Charger input fuse Hella type DC Socket 12V DC Sockets Fuses Control Panel Mounting Base Cable entry ports ...

Page 6: ...se to the main battery on the positive cable Fig 2 Install a second 40A fuse close to the auxiliary battery on the positive cable Make sure all connections are secure and terminated correctly with appropriate tools The input cables must be terminated with a RED 50A coupler matching the input on the DC Distribution Box marked MAIN BATT If solar panels are used they can be connected to the input mar...

Page 7: ...e main wire harness from the circuit The cover can now be completely removed cable entry holes Use a screw driver or flat tool to open the desired 2 Open the cover slightly and unplug the remote monitor feed cable Fit standard cable grommets into the open holes Feed the auxiliary battery cables through the grommets 5 1 Remove the screws holding the cover on the left and right hand sides of the enc...

Page 8: ...ont Make sure the terminal screw is tight Feed the positive battery cable through the grommet and connect it to the top terminal of the main switch Tighten the cable grommets when done 2 Connect the larger ring to the GND terminal Connect the smaller ring of the sensor to the terminal marked Sense Feed the remote temperature sensor wire together with the positive or negative battery cables Tip Fee...

Page 9: ...g and flooded high cycle batteries Used for flooded deep cycle calcium and maintenance free batteries Used for all types of AGM and Gel batteries Battery Types DC DC Battery Charger Battery Float Li ion Wet Ca AGM Gel Charge OK To change this press the Battery button until the desired type is selected The AGM battery type is the default factory setting Ensure the main breaker switch is in the OFF po...

Page 10: ...ly Charge currents exceeding 10A can then be connected Other charger brands can be connected to one of the grey heavy duty AUXILIARY IN OUT connectors Insert the charger quick connector into the charge port labeled NL5 CHARGER until it clicks securely IGNITION SENSE port This may be the case in some vehicles with Smart Alternators The IGNITION SENSE port increases support for vehicles where the ch...

Page 11: ...rops below 11 5V If solar panels are connected and exposed to sunlight the Distribution Box will seek the maximum power possible from the panels under the present conditions Voltage from the panel must be between 9V and 42V Charge to the auxiliary battery will start once voltage on the MAIN BATT input exceeds 13 2V It will stop charge once voltage drops below 12 6V after a short delay If both MAIN...

Page 12: ... temperature and error conditions are displayed in a choice of 3 user selectable display modes The Remote Monitor provides status about the system on a high contrast LCD screen Lift the dirt cover on the Remote Monitor port Connect the square end of the monitor data cable Press the plug until it clicks securely to the remote port as indicated fig 1 It can fit in one direction only Connect the flat en...

Page 13: ...essing the UP or DOWN buttons Display mode 2 In this mode the status of the main and auxiliary batteries are represented as graphical bar graphs The actual voltages are shown for the respective batteries During a charge cycle the input source ALT or SOLAR is displayed with the actual charge current If there is no active charge cycle STANDBY is displayed The AUX graph is animated during charge and ...

Page 14: ...in use If this symbol and voltage display are flashing the battery is not holding charge and should be tested OVER VOLTAGE PROTECTION The voltage applied to the SOLAR or ALT inputs is too high Ensure the applied voltages are within specification Refer to specifications on page 13 Charge will stop until the system temperature recovers to a safe level This error will also be displayed if the Power P...

Page 15: ...ator Input Turn ON Turn OFF Over Voltage 24V Alternator Input Turn ON Turn OFF Over Voltage Igni on Over ride 12V 24V Turn ON Turn OFF Over Voltage Ba ery charge output Voltage Max Current Max Power Opera ng Temperature Standby Current switch ON Dimensions Remote Display USB charge output each port Ba ery Gauge display range Ba ery Types Bulk Voltage Float Voltage AGM Gel 14 4V 13 6V Standard Wet ...

Page 16: ...14 261 mm 257 mm 20 mm 120 mm 201 mm 171 mm 239 mm Mounting hole locations ...

Page 17: ...to the following National Luna 2 Where parts are replaced by an authorised service agent the labour costs for the work done will be for the owner s given 4 This warranty is valid within the borders of South Africa only 5 National Luna may consider a warranty void if modifications have been made to this product which may cause account This National Luna Warranty supersedes any other advertised Guara...

Page 18: ...gs sockets to be replaced with other compatible modules within the 29mm range The lower group can accommodate the following 29mm modules Dual USB charger Engel plug compatible Screw in DC socket Hella type socket factory fitted Cigarette lighter socket factory fitted 12V DC socket ...

Page 19: ...Remote Monitor NL5 Intelligent Battery Charger Ignition Sense cable Charge Port adapter cable 1m Optional Accessories ...

Page 20: ...BMS 20300 DEC 2020 www nationalluna com National Luna sales and support ...

Reviews: