Specifications
13
Ba ery Temperature Compensa on
High temperature
Low Temperature
Ba ery over-temperature protec on
Device Protec on
Reverse Polarity
Over Voltage
Over Current
Bad Ba ery Detect
-17mV per °C above 30°C
+17mV per °C below 21°C
60°C
Over Temperature
Charge Algorithm
Voltage
Diagnosis
Recovery
Bulk
Absorption
Analysis
Float
Current
Step
1
2
3
4
5
6
Voltage Range
MAIN BATT input
SOLAR PANEL input
Solar Regulator
Type
Output Current
Output Power
12V Alternator Input
Turn ON
Turn OFF
Over-Voltage
24V Alternator Input
Turn ON
Turn OFF
Over-Voltage
Igni on Over-ride (12V / 24V)
Turn ON
Turn OFF
Over-Voltage
Ba ery charge output
Voltage
Max Current
Max Power
Opera ng Temperature
Standby Current (switch ON)
Dimensions
Remote Display
USB charge output (each port)
Ba ery Gauge display range
Ba ery Types
Bulk Voltage
Float Voltage
AGM / Gel
14.4V
13.6V
Standard Wet
14.6V
13.6V
Calcium
14.8V
13.6V
Lithium Ion
14.4V
13.6V
9V - 42V
11V - 32V
13.2V
12.6V
MPPT
375W
25A
14.8V - 16V
-20°C to 85°C
11.5V
23V
15.5V - 16V
31V - 32V
3V -14.8V
25A
375W
26.4V
23.2V
29.6V - 31V
12.0V
24.0V
257mm x 261mm x 120mm
Op onal
10.7V - 14.7V
5V-3A, 9V-2A, 12V-1.5A