Changing battery type
7
- Replace the cover of the DC-DC system.
- Re-connect the remote monitor plug and close the cover.
- Re-install and tighten the screws that were removed earlier.
Once the preferred battery type is selected, disconnect the power source.
- Re-connect the wire harness and any other wires removed earlier.
- The auxiliary battery can now be connected.
Wet
AGM / Gel
Ca+
Li-ion
Used for automotive Lithium-ion or
LiFePO4 batteries.
Used for regular automotive starting
and flooded high-cycle batteries.
Used for flooded deep-cycle, calcium
and maintenance-free batteries.
Used for all types of AGM and Gel
batteries.
Battery Types
DC-DC Battery Charger
Battery
Float
Li-ion
Wet
Ca+
AGM/Gel
Charge
OK /
To change this, press
the "Battery" button
until the desired type is
selected.
The AGM battery type
is the default factory
setting.
Ensure the main breaker switch is in the OFF position then connect a 12V power source to the MAIN
BATTERY or SOLAR inputs. The system will indicate the current battery type.
With the cover still removed, the auxiliary battery type can be selected.
Press the "Battery" button to select the desired battery type.
Reassembly