Chapter 4
VXIpc 700 Series Configuration and Installation
©
National Instruments Corporation
4-3
VXIpc 800/700 Series User Manual
Table 4-1 lists the factory-default settings and options for the onboard
jumpers.
Configuring the VXIpc 700 Series
This section describes how to configure the following options on the
VXIpc-700.
•
VXIbus Slot 0/Non-Slot 0
•
Trigger Input Termination
•
EEPROM
•
Installed system RAM
How to Remove the Metal Enclosure
The VXIpc-700 is housed in a metal enclosure comprised of a top and
bottom cover to improve EMC performance and to provide easy
handling. You must remove the top cover to change many of the switch
and jumper settings. You must also remove the top cover to change the
amount of DRAM installed on the module.
Table 4-1. VXIpc 700 Series Hardware Default Settings
Jumper/
Switch
Default
Setting
Optional
Setting
W1
Enable automatic Slot 0
detection
Force Slot 0;
Force Non-Slot 0
W3
Normal CMOS operation
Clear CMOS
W6
Enable Ethernet EEPROM
configuration
Disable Ethernet EEPROM
configuration (uses default
power on values)
W10
Enable MITE
self-configuration
Disable MITE
self-configuration
W7
MITE user configuration
MITE factory configuration
W12
No termination on external
trigger input
Terminate external trigger
input to 50
Ω