Chapter 4
VXIpc 700 Series Configuration and Installation
VXIpc 800/700 Series User Manual
4-8
©
National Instruments Corporation
Figure 4-6. System CMOS
Ethernet Power-On Defaults
The VXIpc-700 Ethernet circuitry loads its power-on settings from an
EEPROM. You should not change W6 from its default setting;
however, the jumper setting required to do so is included in Figure 4-7
for informational purposes.
Figure 4-7. Ethernet Power-On Defaults
Installing the VXIpc 700 Series
This section contains general installation instructions for the
VXIpc-700. Consult your VXIbus mainframe user manual or technical
reference manual for specific instructions and warnings.
1.
Plug in your mainframe before installing the VXIpc-700. The
power cord grounds the mainframe and protects it from electrical
damage while you are installing the module.
Warning: To protect both yourself and the mainframe from electrical hazards,
the mainframe should remain off until you are finished installing the
VXIpc-700 module.
2.
Remove or open any doors or covers blocking access to the
mainframe slots.
3.
If you are installing the VXIpc-700 into a D-size mainframe,
install a support designed for installing C-size boards in D-size
W3
W3
a. Normal Operation
(Default)
b. Clear CMOS
Contents
a. Ethernet Power-On Defaults
Loaded from EEPROM
b. Hardwired Ethernet Values
W6
W6