Table 3-1 lists the factory-default settings and options for the onboard
jumpers and switches.
Table 3-1. VXIpc 800 Series Hardware Default Settings
Jumper/
Switch
Default
Setting
Optional
Setting
W1
Supply SCSI termination
power
Disable SCSI termination
W2
Normal CMOS operation
Clear CMOS
W4
LPT1 uses DMA Channel 1
LPT uses DMA Channel 3
W13
Enable automatic Slot 0
detection
Force Slot 0;
Force Non-Slot 0
S1
Enable Ethernet EEPROM
configuration
Disable Ethernet EEPROM
configuration (uses default
power on values)
S2
Enable MITE
self-configuration
Disable MITE
self-configuration
S3
Source CLK10 from
onboard oscillator
Source CLK10 from SMB
S4
Non-inverted CLK10
output
Inverted CLK10 output
S5
Receive CLK10 input from
SMB
Source CLK10 output to
SMB
S6
No termination on CLK10
input
Terminate CLK10 input
to 50
Ω
S7
No termination on external
trigger input
Terminate external trigger
input to 50
Ω
S8
GPIB uses IRQ11
GPIB uses IRQ5
S9
MITE user configuration
MITE factory configuration