2-34
|
ni.com
Chapter 2
Basic Functions
CF24 Multichannel (VMCB) Domain Number Parameter
Set the multichannel domain number. RMX models that have the same domain number perform
multichannel operations. If you do not want to use the multichannel function, set this to 0 (this
is the factory default setting).
If 5700 or DCS emulation is selected, you cannot use multichannel. This parameter is applied
when you turn the POWER switch off and on or when you execute CF34.
CF25 Multichannel (VMCB) Channel Number
Set the multichannel channel number. Specify a unique number on the network. If you do not
want to use the multichannel function, set this to 0 (this is the factory default setting).
If 5700 or DCS emulation is selected, you cannot use multichannel. This parameter is applied
when you turn the POWER switch off and on or when you execute CF34.
CF30 to CF33 IP Address Display
These parameters display the set IP addresses. These parameters are only displayed when you
are using the LAN interface.
To set a fixed IP address use CONFIG parameters CF42 to CF45 and then apply the LAN
settings with CF40. You can also set a fixed IP address when you access the power supply
through a web browser. When you access the power supply through a web browser, do so under
conditions in which a DHCP server or AUTO IP can be used.
Value
Parameter Description
0
The multichannel function is not used (factory default setting).
1 to 254
The domain number when the multichannel function is used.
Value
Parameter Description
0
The RMX is used as a master unit on the multichannel network
(factory default setting).
1 to 30
1 to 30 The RMX is used as a slave unit with this channel number
on the multichannel network.
Parameter Number
Display
Description
CF30
0 to 255
Displays the first IP address number
CF31
0 to 255
Displays the second IP address number