2-20
|
ni.com
Chapter 2
Basic Functions
You cannot stop communication monitoring with the *RST, *RCL, or *CLS command. In the
alarm state, turn off communication monitoring before clearing the alarm.
Figure 2-26.
Alarm Indication when WATCHDOG has been Activated
CONFIG Settings
Use the CONFIG settings to set the RMX programmable power supply’s system configuration.
You can set and display the following parameters in the CONFIG settings.
Effect
column
† indicates a parameter that may be affected when the panel
settings are reset (CF00), or when a preset memory entry is
loaded.
* indicates a parameter that may be affected when the master unit,
the slave unit, or the number of units is changed (CF01).
‡ indicates a parameter that may be affected when the LAN
interface settings are reset (CF40:LCi/dEF).
Note
column
A
indicates a parameter that is applied immediately.
B
indicates a parameter that is applied when the RMX
programmable power supply is turned on.
C
indicates a parameter that is applied when CF40 “APPL” is
executed.
Figure 2-27.
CONFIG Setting and Display Examples
Lit
Parameter number,
CF (CONFIG)
+ a two-digit number
Setting display
Lit