background image

© 2017 National Instruments. All rights reserved. 

377029B-01

May17

Refer to the 

NI Trademarks and Logo Guidelines 

at 

ni.com/trademarks

 for more information on National Instruments trademarks. Other 

product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National 
Instruments products/technology, refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on your media, or the 

National Instruments Patents Notice

 at 

ni.com/patents

. You can find information about end-user license agreements (EULAs) and third-party 

legal notices in the readme file for your NI product. Refer to the 

Export Compliance Information 

at 

ni.com/legal/export-compliance

 

for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES 
NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR 
ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable 
limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

Waste Electrical and Electronic Equipment (WEEE)

EU Customers

At the end of the product life cycle, all products 

must

 be sent to 

a WEEE recycling center. For more information about WEEE recycling centers, 
National Instruments WEEE initiatives, and compliance with WEEE Directive 
2002/96/EC on Waste and Electronic Equipment, visit 

ni.com/environment/

weee

.

Worldwide Support and Services

The NI website is your complete resource for technical support. At 

ni.com/support

 you have 

access to everything from troubleshooting and application development self-help resources to 
email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and 

other services.

Visit 

ni.com/register

 to register your NI product. Product registration facilitates technical 

support and ensures that you receive important information updates from NI.

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European 
Communities using the manufacturer’s declaration of conformity. This system affords the user 
protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC 
for your product by visiting 

ni.com/certification

. If your product supports calibration, 

you can obtain the calibration certificate for your product at 

ni.com/calibration

.

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 
78759-3504. NI also has offices located around the world. For telephone support in the United 
States, create your service request at 

ni.com/support

 or dial 1 866 ASK MYNI (275 6964). 

For telephone support outside the United States, visit the Worldwide Offices section of 

ni.com/niglobal

 to access the branch office websites, which provide up-to-date contact 

information, support phone numbers, email addresses, and current events.

⬉ᄤֵᙃѻક∵ᶧ᥻ࠊㅵ⧚ࡲ⊩ ˄Ё೑

RoHS

˅

Ё೑ᅶ᠋

National Instruments

ヺড়Ё೑⬉ᄤֵᙃѻકЁ䰤ࠊՓ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ

 

(RoHS)

DŽ݇Ѣ

National Instruments

Ё೑

RoHS

ড়㾘ᗻֵᙃˈ䇋ⱏᔩ

ni.com/

environment/rohs_china

DŽ

(For information about China RoHS compliance, 

go to 

ni.com/environment/rohs_china

.)

Summary of Contents for PXIe-4310

Page 1: ...necting to other modules that could be damaged by the voltage present on the terminal block However you should only use these terminal blocks with their supported modules Caution Do not supply hazardo...

Page 2: ...Support and Services 24 Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility EMC stated in the p...

Page 3: ...ifications provided by the manufacturer You are responsible for verifying the safety compliance of third party connectors and their usage according to the relevant standard s including UL and CSA in N...

Page 4: ...st supported in NI DAQmx 17 1 Note For detailed NI software version support refer to the NI DAQmx Readme Back up any applications before upgrading software or modifying the application Unpack and Inst...

Page 5: ...ssis Slot Type Symbol Location 5 Remove the filler panel and touch any metal part of the chassis to discharge static electricity 6 Place the module edges into the module guides at the top and bottom o...

Page 6: ...ut the terminal block being connected to the PXIe 4310 A terminal block is required to make connections to the module To connect signals to the TB 4310 10V TB 4310 600V refer to Figures 3 and 4 while...

Page 7: ...determine the function of the terminal The PXIe 4310 User Manual provides more detailed wiring information Make sure no exposed wire extends past the screw terminal Exposed wire increases the risk of...

Page 8: ...elding the signals 7 Reinstall the strain relief bar and tighten the strain relief screws 8 Use tie wraps to connect the shielded signal wires to the tie wrap holes for additional strain relief when n...

Page 9: ...rminal block 3 Tighten the mounting screw at the top of the terminal block to attach it to the module Note For safety purposes and to prevent damage to equipment when high voltages are present all PXI...

Page 10: ...ystem 2 Launch MAX 3 Expand Devices and Interfaces and expand the chassis in which the module is located to confirm that MAX detects the module and terminal block The terminal block should appear bene...

Page 11: ...Refer to the device specifications to find your device warm up time This function measures the onboard reference voltage of the device and adjusts the self calibration constants to account for any err...

Page 12: ...nd Tasks Refer to the NI DAQmx Help for complete information about channels and tasks Use the DAQ Assistant to configure virtual channels and tasks in MAX or in your application Configure a Task Using...

Page 13: ...on software Text based code examples are located at All Programs National Instruments NI DAQmx NI DAQmx Examples Modify example code and save it in an application or use examples to develop a new appl...

Page 14: ...emove the terminal block a Raise the latch release using a flathead screwdriver to disengage the latch b With the latch release raised grasp the terminal block and pull it away from the module Figure...

Page 15: ...tive screws on the top and bottom of the module Caution Do not pull the front panel to remove the module Doing so may cause module components to come into contact with adjacent modules causing damage...

Page 16: ...odular Instrument and click Finish 4 Type 4310 in the text box at the top of the window 5 Select the device from the list provided 6 Click OK Once you have created the simulated PXIe module you can si...

Page 17: ...s of a search for relevant documents If you do not have web access documents for supported modules are included on the NI DAQmx media Troubleshooting Go to ni com kb If you need to return your Nationa...

Page 18: ...pF TB 4310 600V AI to AI 2 M Typical Accuracy TB 4310 600V INL error 51 ppm of range Stability Gain drift 15 ppm C Reference tempco 5 ppm C Attenuator Self Heating 26 V V for each volt beyond 120 V No...

Page 19: ...ise 0 Noise Uncertainty for a coverage factor of 3 and averaging 10000 points Typical Accuracy Example Accuracy at full scale is determined using the following assumptions TempChangeFromLastExternalCa...

Page 20: ...dry and free from contaminants before returning it to service Environmental Maximum altitude 2 000 m 800 mbar at 25 C ambient temperature Pollution Degree 2 Indoor use only Operating Environment Ambie...

Page 21: ...half sine 11 ms pulse Tested in accordance with IEC 60068 2 27 Meets MIL PRF 28800F Class 2 limits Random vibration Operating 5 Hz to 500 Hz 0 3 grms Non operating 5 Hz to 500 Hz 2 4 grms Tested in ac...

Page 22: ...This product meets the requirements of the following EMC standards for electrical equipment for measurement control and laboratory use EN 61326 1 IEC 61326 1 Class A emissions Basic immunity EN 55011...

Page 23: ...requirements of applicable European Directives as follows 2014 35 EU Low Voltage Directive safety 2014 30 EU Electromagnetic Compatibility Directive EMC Online Product Certification Refer to the prod...

Page 24: ...on Waste and Electronic Equipment visit ni com environment weee Worldwide Support and Services The NI website is your complete resource for technical support At ni com support you have access to every...

Reviews: