background image

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the
European Communities using the manufacturer’s declaration of conformity. This system
affords the user protection for electromagnetic compatibility (EMC) and product safety. You
can obtain the DoC for your product by visiting 

ni.com/certification

. If your product supports

calibration, you can obtain the calibration certificate for your product at 

ni.com/calibration

.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway,
Austin, Texas, 78759-3504. National Instruments also has offices located around the world.
For telephone support in the United States, create your service request at 

ni.com/support

 or

dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the

Worldwide Offices

 section of 

ni.com/niglobal

 to access the branch office websites, which

provide up-to-date contact information, support phone numbers, email addresses, and current
events.

Refer to the 

NI Trademarks and Logo Guidelines

 at 

ni.com/trademarks

 for information on National Instruments

trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective
companies. For patents covering National Instruments products/technology, refer to the appropriate location: 

Help

»

Patents

 in your software, the 

patents.txt

 file on your media, or the 

National Instruments Patent Notice

 at 

ni.com/

patents

. You can find information about end-user license agreements (EULAs) and third-party legal notices in the

readme file for your NI product. Refer to the 

Export Compliance Information

 at 

ni.com/legal/export-compliance

 for

the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other
import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE
INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government
Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited
rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

© 2014 National Instruments. All rights reserved.

376280A-01

Oct14

Summary of Contents for NI PXIe-5624R

Page 1: ...rs Documentation Note The NI 5624R can be used on its own or as a component of certain NI vector signal analyzers Refer to the documentation for your vector signal analyzer for information about using...

Page 2: ...ith shielded cables and accessories Caution To ensure the specified EMC performance the length of all I O cables must be no longer than 3 m 10 ft Verifying the System Requirements To use the NI 5624R...

Page 3: ...ems A PXI Express chassis and chassis documentation The NI PXIe 1085 chassis is one available option for your PXI Express device For more information about compatible chassis options visit ni com info...

Page 4: ...NI 5624R You can use the instrument design libraries to control or customize your NI 5624R device to suit the needs of your application This software offers many LabVIEW libraries to assist you in con...

Page 5: ...in the installation prompts to install the default installation Windows users may see access and security messages during installation Accept the prompts to complete the installation Note The default...

Page 6: ...ack plastic connectors from all the captive screws on the module front panel 7 Identify a supported slot in the chassis The following figure shows the symbols that indicate the slot types Figure 2 Cha...

Page 7: ...sis using the front panel mounting screws Note Tightening the top and bottom mounting screws increases mechanical stability and also electrically connects the front panel to the chassis which can impr...

Page 8: ...NI 5624R Front Panel The NI 5624R front panel contains five connectors and two LEDs Figure 4 NI 5624R IF Digitizer Module Front Panel ACCESS ACTIVE 8 ni com NI PXIe 5624R Getting Started Guide...

Page 9: ...function digital I O DIO connector for triggers or events CLK IN SMA connector Input for an external ADC Clock Sample Clock or Reference Clock to the digitizer CLK OUT SMA connector Output for an ADC...

Page 10: ...ware MAX informs other programs about which devices reside in the system and how they are configured MAX is automatically installed with NI LabVIEW Instrument Design Libraries for IF Digitizers 1 Laun...

Page 11: ...ule and select Self Calibrate on the device toolbar In LabVIEW select the Self Calibrate VI located at FPGA Interface Software Designed Instruments IF Digitizers Calibration Making a Measurement with...

Page 12: ...nel System and Maintenance Device Manager Windows XP Select Start Control Panel System Hardware Device Manager 5 If you are using a PXI controller verify that a National Instruments entry appears in t...

Page 13: ...EW 2014 FPGA Module Help Learn LabVIEW Basics NI 5624R Sample Projects Note The NI IF Digitizers Help is an HTML version of a traditional user manual that includes detailed information about device fe...

Page 14: ...rks and Logo Guidelines at ni com trademarks for information on National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective compa...

Reviews: