NI-6589

2022-07-06

Summary of Contents for NI-6589

Page 1: ...NI 6589 2022 07 06 ...

Page 2: ... 5 Preparing the Environment 6 Installing the NI 6589 7 Confirming that Measurement Automation Explorer MAX Recognizes the Device 7 Cables 7 Accessories 8 Front Panel and Connector Pinouts 10 Block Diagrams 13 Component Level Intellectual Property CLIP 15 NI 6589 CLIP 15 Clocking 19 Where to Go Next 20 Worldwide Support and Services 21 ni com 2 NI 6589 ...

Page 3: ...e designed to provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment This product is intended for use in industrial locations However harmful interference may occur in some installations when the product is connected to a peripheral device or test object or if the product is used in residential or commercial a...

Page 4: ...s for your FlexRIO FPGA module or Controller for FlexRIO Getting started guide for your adapter module Available from the Start menu and at ni com manuals Contains signal information examples and CLIP details for your adapter module Specifications document for your adapter module Available from the Start menu and at ni com manuals Contains specifications for your adapter module LabVIEW FPGA Module...

Page 5: ...mple Finder In LabVIEW click Help Find Examples Hardware Input and Output FlexRIO Contains examples of how to run FPGA VIs and Host VIs on your device IPNet Located at ni com ipnet Contains LabVIEW FPGA functions and intellectual property to share FlexRIO product page Located at ni com flexrio Contains product information and data sheets for FlexRIO devices Table 1 FlexRIO Documentation Locations ...

Page 6: ...all a device if it appears damaged in any way 3 Unpack any other items and documentation from the kit Store the devices in the antistatic package when they are not in use Preparing the Environment Ensure that the environment you are using the NI 6589 in meets the following specifications Operating temperature IEC 60068 2 1 IEC 60068 2 2 0 C to 55 C Operating humidity IEC 60068 2 56 10 to 90 RH non...

Page 7: ...X is automatically installed with FlexRIO Support 1 Launch MAX by navigating to Start All Programs National Instruments NI MAX or by clicking the NI MAX desktop icon 2 In the Configuration pane double click Devices and Interfaces to see the list of installed devices Installed devices appear under the name of their associated chassis 3 PXI and PXI Express devices only Expand your Chassis tree item ...

Page 8: ... cable NI part number 192344 01 or the NI SHB12X H3X24 differential flying lead cable NI part number 196236 1R5 to connect to the DDC connector You can also connect the NI SMA 2164 accessory to the NI 6589 through the SHB12X B12X shielded cable for testing and debugging Note If you design a custom cabling solution with the DDC connector 779157 01 and SHB12X B12X shielded cable 192344 01 the NI 658...

Page 9: ...3 A 0 1 I O_ 12 IO_4 IO_5 IO_8 IO_2 IO_9 IO_1 PFI_3 CLK_LVDS PFI_2 PFI_1 VOS VOS VOS VOS VOS VOS VOS VOS VOS VOS VOS IO_0 VOS VOS S N VOS VOS VOS VOS VOS VOS VOS VOS 6 1 7 0 4 0 4 9 19 3 1 10 7 3 6 4 6 7 5 2 5 5 5 8 4 3 4 6 3 4 3 7 2 2 2 5 2 8 13 16 1 4 7 1 VOS NI SMA 2164 DIFFERENTIAL DIGITAL I O ACCESSORY FOR PATENTS NI COM PATENTS COPYRIGHT 2005 NI 6587 PFI 0 CLOCK IN 1 Gbps LVDS 1 PXI PXIe Cha...

Page 10: ... using the VHDCI Connector application note Visit ni com info and enter the Info Code rdinwa to download this note If you are designing a custom accessory to use with a device that uses an InfiniBand connector you can also purchase this connector from NI Note If you design a custom cabling solution with the DDC connector 779157 01 and SHB12X B12X shielded cable 192344 01 the NI 6589 pinout is reve...

Page 11: ...D DIO 8 GND DIO 9 GND DIO 10 GND DIO 11 GND DIO 12 GND DIO 13 GND DIO 14 GND DIO 15 GND GND GND GND GND PFI 1 PFI 2 PFI 3 DIO 0 DIO 1 DIO 2 DIO 3 DIO 4 DIO 5 DIO 6 DIO 7 DIO 8 DIO 9 DIO 10 DIO 11 DIO 12 DIO 13 DIO 14 DIO 15 1 3 2 4 6 5 7 9 8 10 12 11 13 15 14 16 18 17 19 21 20 22 24 23 25 27 26 28 30 29 31 33 32 34 36 35 37 39 38 40 42 41 43 45 44 46 48 47 49 51 50 52 54 53 55 57 56 58 60 59 61 63...

Page 12: ... terminal for channel PFI 0 CLOCK IN CLOCK IN Clock External single ended clock input terminal Table 2 SMA Connector Names and Descriptions The following table contains DDC pin location information for the NI 6589 The signal names listed in this table refer to the signals shown in the front panel pinout Signal Name Pin s Signal Type Signal Description DDC CLK OUT 65 Control Positive terminal for t...

Page 13: ...10 13 16 19 22 25 28 31 34 37 40 42 46 49 52 55 58 69 Ground Ground reference for signals Table 3 NI 6589 DDC Connector Names and Descriptions For more detailed information about the NI 6589 front panel connectors refer to the NI 6589 Specifications Block Diagrams The following figures show the data flow through the NI 6589 Single ended data lines use standard clock levels to interpret data as eit...

Page 14: ...ion and PFI 1 4 Figure 6 Single Ended PFI Lines Data from NI FlexRIO FPGA Module GPIO Output Output Enable from NI FlexRIO FPGA Module GPIO Direction Data to NI FlexRIO FPGA Module GPIO Input SE_PFI 1 3 and PFI 0 50 Ω Figure 7 Clock Output Signals Clock from NI FlexRIO FPGA Module GPIO Output Output Enable from NI FlexRIO FPGA Module GPIO Direction DDC CLK OUT LVDS LVDS DDC CLK OUT Switch 110 Ω 10...

Page 15: ... Property CLIP The LabVIEW FPGA Module includes component level intellectual property CLIP for HDL IP integration FlexRIO devices support two types of CLIP user defined and socketed User defined CLIP allows you to insert HDL IP into an FPGA target enabling VHDL code to communicate directly with an FPGA VI Socketed CLIP provides the same IP integration of the user defined CLIP but it also allows th...

Page 16: ...LVDS clock output signal Four single ended PFI lines One single ended clock input signal Provides read write access to all LVDS and single ended channels using a channel based interface You can access the LVDS data and PFI channels using a U16 data type in which the top six bits are unused Each LVDS line PFI line and clock output is connected to an OSERDES or ISERDES block that serializes or deser...

Page 17: ...FPGA module signals necessary for designing custom component level IP CLIP NI 6589 FlexRIO FPGA Module Signal Name GPIO Input GPIO Output GPIO Direction PFI 0 GPIO_2_n GPIO_5_n GPIO_6_n as enable CLOCK IN GClk_SE Table 5 NI 6589 SMA Signals and FlexRIO FPGA Module Signals The following table lists the NI 6589 DDC connector signals and corresponding FlexRIO FPGA module signals necessary for designi...

Page 18: ...7 GPIO_5 DIO 5 GPIO_61_n GPIO_27_n DIO 6 GPIO_55 GPIO_22 GPIO_6 DIO 6 GPIO_55_n GPIO_22_n DIO 7 GPIO_54 GPIO_18 GPIO_7 DIO 7 GPIO_54_n GPIO_18_n DIO 8 GPIO_53 GPIO_30 GPIO_8 DIO 8 GPIO_53_n GPIO_30_n DIO 9 GPIO_52 GPIO_25 GPIO_9 DIO 9 GPIO_52_n GPIO_25_n DIO 10 GPIO_51 GPIO_21 GPIO_10 DIO 10 GPIO_51_n GPIO_21_n DIO 11 GPIO_50 GPIO_17 GPIO_2 DIO 11 GPIO_50_n GPIO_17_n DIO 12 GPIO_49_CC GPIO_29 GPIO...

Page 19: ...o the FlexRIO Help for more information about FlexRIO CLIP items configuring the NI 6589 with a socketed CLIP and a list of available socketed CLIP signals Clocking The clocks on the NI 6589 control the sample rate and other timing functions on your FlexRIO system The following figure shows the NI 6589 clock sources routed through the crosspoint switch The Generation Bank I O clock PFI Bank I O cl...

Page 20: ...terminal is accessed with a U8 data type The following table shows the values of the crosspoint switch clock options Value Clock Option 0 Tristate Output disabled high impedance 2 Sync Clock PXI Express Only Clock from PXI Express backplane You can select PXI_CLK10 or DStarA in the Details category of the IO Module Properties dialog box 3 Adapter Module Onboard Clock Clock generated from the Si570...

Page 21: ...enu Worldwide Support and Services The NI website is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Application Engineers Visit ni com services for NI Factory Installation Services repairs extended warranty and other services Visit ni com register...

Page 22: ...s located around the world For telephone support in the United States create your service request at ni com support or dial 1 866 ASK MYNI 275 6964 For telephone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information support phone numbers email addresses and current events ni com 22 ...

Reviews: