Chapter 5
LabVIEW RT Programming
5-2
ni.com
LabVIEW RT applications that have any of the unsupported functionality
listed above may or may not work as expected on the FP-20
xx
.
Complete the following steps on the host PC to target LabVIEW RT to your
FP-20
xx
:
1.
Start LabVIEW.
2.
Open a new VI.
3.
Select
Operate»Switch Execution Target
to open the Select Target
Platform dialog box, shown in the following figure.
4.
Select your target platform from the pull-down menu.
5.
Select
RT Engine on Network
to target your FP-20
xx
.
Note
When targeting LabVIEW RT to an FP-20
xx
network module, the module does not
need to reside on the same subnet as the host PC.
6.
Enter the IP address and password you specified for the FP-20
xx
in
Remote System Explorer. If no password is specified for the FP-20
xx
,
leave the password field blank.
If the IP address of the host PC appears in the
RT Target: Access
list of the FP-20
xx
, you do not need to enter the password. Refer to
the
section for more information about
RT Target: Access
.
7.
Click
OK
.