background image

Documentation

Consult the following documents for information about the FieldDAQ device and the
NI-DAQmx driver. All documents are available on 

ni.com/manuals

; help files install with the

software.

FD-11613/11614 Quick Start 

—Instructions for installing and configuring your

FieldDAQ device.

FD-11613 User Guide

 or 

FD-11614 User Guide

—Information about your FieldDAQ

device.

FD-11613 Specifications

 or 

FD-11614 Specifications

—Detailed specifications for

your FieldDAQ device.

NI-DAQmx Readme

—Operating system and application software support in

NI-DAQmx.

NI-DAQmx Help

—Information about creating applications that use the NI-DAQmx

driver.

NI-DAQmx C Reference Help

—Reference information for NI-DAQmx C functions

and NI-DAQmx C properties.

Test Equipment

The following table lists the equipment required for calibrating your FD-11613 or FD-11614.
If you do not have the recommended instruments, use the minimum requirements to select
substitute equipment.

Table 2. Recommended Test Equipment

Equipment

Recommended Model

Minimum Requirements

 

 

 

Calibrator

Fluke 5522A locked in the 3.3 V
range

A high-precision voltage source with an
uncertainty of ≤70 ppm when sourcing
up to 50 µA.

Mini TC (x8) Omega SMPW-U-M

U type

Test Conditions

The following setup and environmental conditions are required to ensure the FD-11613/11614
meets published specifications:

2

  | 

ni.com

  | 

FD-11613/11614 Calibration Procedure

Summary of Contents for FD-11613

Page 1: ...to Go for Support 10 Software Requirements Calibrating the FD 11613 or FD 11614 requires the installation of NI DAQmx on the calibration system NI recommends using the latest NI DAQmx driver Earliest...

Page 2: ...pplications that use the NI DAQmx driver NI DAQmx C Reference Help Reference information for NI DAQmx C functions and NI DAQmx C properties Test Equipment The following table lists the equipment requi...

Page 3: ...rt Note You must install NI DAQmx 18 1 or later for device calibration support 2 Set up the FieldDAQ device as outlined in the FD 11613 11614 Quick Start 3 Configure the FieldDAQ device in Measurement...

Page 4: ...of operation and test points required to verify the FieldDAQ device The verification procedures assume that adequate traceable uncertainties are available for the calibration references Complete the...

Page 5: ...Accuracy Under Calibration Conditions 4 Set the calibrator to Operate mode OPR 5 Acquire and average samples a Create and configure an AI voltage channel on the FieldDAQ device according to the follow...

Page 6: ...om each channel and average the readings e Clear the task 13 Compare the average to the limits in the following table Table 6 FD 11613 11614 Voltage Verification Test Limits for Zero Test Points ADC T...

Page 7: ...eldDAQ device as shown in the following figure Figure 3 Bank 1 Voltage Channel Adjustment Connections TC0 TC0 HI LO TC1 TC1 TC6 TC6 TC7 TC7 Calibrator FD 11613 11614 TC2 TC2 TC3 TC3 TC4 TC4 TC5 TC5 Ba...

Page 8: ...gh g for each reference value in the array of adjustment points 4 Disconnect the calibrator from the FieldDAQ device 5 FD 11614 Connect the calibrator to Bank 2 of the FD 11614 as shown in the followi...

Page 9: ...onditions The values in the following table are based on calibrated scaling coefficients which are stored in the onboard EEPROM The following accuracy table is valid for calibration under the followin...

Page 10: ...d Logo Guidelines at ni com trademarks for information on NI trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents coverin...

Reviews: