cRIO-9025 Operating Instructions and Specifications
10
ni.com
CONSOLE OUT Switch
With a serial-port terminal program, you can use the CONSOLE OUT
switch to read the IP address and firmware version of the controller. Use a
null-modem cable to connect the serial port on the controller to a computer.
Push the switch to the ON position. Make sure that the serial-port terminal
program is configured to the following settings:
•
9,600 bits per second
•
Eight data bits
•
No parity
•
One stop bit
•
No flow control
The serial-port terminal program displays the IP address and firmware
version of the controller, and alerts you when you connect an unsupported
USB device to the controller. Keep this switch in the OFF position during
normal operation.
IP RESET Switch
Push the IP RESET switch to the ON position and reboot the controller
to reset the IP address and other TCP/IP settings of the controller to the
factory defaults. Refer to the
Resetting the Network Configuration of the
Controller
section for more information about resetting the IP address.
NO APP Switch
Push the NO APP switch to the ON position to prevent a LabVIEW startup
application from running on the controller when the controller powers on.
If you want to permanently disable the application from running when
the controller powers on, you must disable it in LabVIEW. To run an
application when the controller powers on, push the NO APP switch to
the OFF position, create an application using the LabVIEW Application
Builder, and configure the application in LabVIEW to launch when the
controller powers on. If you already have an application configured to
launch when the controller powers on and you push the NO APP switch
from ON to OFF, the startup application is automatically enabled. For more
information about automatically launching VIs when the controller powers
on and disabling VIs from launching when the controller powers on, refer
to the
LabVIEW Help
.
USER1 Switch
You can define the USER1 switch for your application. To define the
purpose of this switch in your embedded application, use the RT Read
Switch VI in your LabVIEW RT embedded VI. For more information
about the RT Read Switch VI, refer to the
LabVIEW Help
.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com