Figure 7.
cRIO-9068 Ambient Temperature Location
25.4 mm
(1.00 in.)
1
1
63.5 mm
(2.50 in.)
25.4 mm
(1.00 in.)
63.5 mm
(2.50 in.)
1. Location for measuring the ambient temperature
Mounting the Device Directly on a Flat Surface
For environments with high shock and vibration, NI recommends mounting the cRIO-9068
directly on a flat, rigid surface using the mounting holes in the cRIO-9068.
What to Use
•
cRIO-9068
•
Screwdriver, Phillips #2
•
M4 or number 8 screw (x3), user-provided, longer than 19 mm (0.75 in.) to pass all the
way through the cRIO-9068
What to Do
Complete the following steps to mount the cRIO-9068 directly on a flat surface.
NI cRIO-9068
1. Prepare the surface for mounting the cRIO-9068 using the
.
2. Align the cRIO-9068 on the surface.
3. Fasten the cRIO-9068 to the surface using the M4 or number 8 screws appropriate for the
surface. Tighten the screws to a maximum torque of 1.3 N · m (11.5 lb · in.).
Surface Mounting Dimensions
The following figure shows the surface mounting dimensions for the cRIO-9068.
6
|
ni.com
|
Maintaining NI CMS-9068, MMS-9068, and EMSA-9068 Hardware for an NI InsightCM Device
Summary of Contents for CMS-9068