Getting Started with NI 9501 Modules and NI SoftMotion
|
© National Instruments
|
7
Step 3: Connect the NI 9501 to the NI PS-16
Power Supply
Tip
Refer to the
NI PS-16 Power Supply User Manual and Specifications
for more
information about connecting and using the NI PS-16 power supply.
Complete the following steps to connect the NI 9501 module to the NI PS-16 power supply.
Tip
Refer to the
NI 9501 Operating Instructions and Specifications
for more
information about module power supply requirements.
1.
Connect the NI 9501 Vsup (pin 8) to one of the two (+) terminals on the NI PS-16.
2.
Connect the NI 9501 COM (pin 7) to one of the two (-) terminals on the NI PS-16.
3.
Connect the power supply to AC power.
Step 4: Connect the System to AC Power
Complete the following steps to power on the system.
1.
Connect the controller power supply to AC power.
2.
Connect the NI 9501 power supply to AC power.
Step 5: Install Software on and Configure the
NI RT Controller
This step covers installing and configuring the software for the NI 9501 stepper drive module.
It assumes that all required software from the
on the host machine.
Complete the following steps to configure the controller and install software on it.
Note
The Measurement & Automation Explorer (MAX) user interface may not
match these steps exactly depending on which version of MAX you are using.
1.
Launch Measurement & Automation Explorer (MAX) on the development computer by
double-clicking the MAX icon on the desktop (
), or by selecting
Start»
All Programs»National Instruments»Measurement & Automation
.
2.
Expand the
Remote Systems
tree.
3.
Highlight your device.
Note
If you do not see the controller, you may need to disable the firewall on the
development computer. Go to
ni.com/info
and enter
RIOMAXTroubleshoot
for more information.