3. Technical Characteristics
3.1 Performance
Model
Vin DC
VDC
Vin AC
VAC
P1 max
W
SUND 50
90 - 400
1 x 90 - 265
800
P.F. line side (with AC power supply)
Power supply frequency (with AC power supply): 50 - 60 Hz (+/- 2%)
Stocking temperature: -30 to 70 °C (-22 to 158 °F)
Max. ambient temperature: 50°C (122 °F)
Max liquid temperature: 40 °C (104 °F)
Max. altitude at rated load: 1000 m
Max relative humidity: 95% without condensation
Max working pressure: 3 bar
Max suction head: 2,5 m
Motor insulation class: F
Grade of protection: IP55 (NEMA 4)*
Connectivity: Bluetooth SMART communication for monitoring and programming, Modbus RTU RS485.
* Protect the device from direct exposure to sunlight and atmospheric agents