5.1 Monitoring and programming
In order to access to parameters monitoring and programming it is necessary to use a smartphone or tablet with Bluetooth
4.0 (BTLE) and Nastec NOW App installed. The App is available on Android or iOS and can be downloaded free of charge
through the on-line stores.
It is possible to disable the BTLE connection by removing power supply, wait at least 30 seconds till the red STAND-BY led is
OFF, keep pressed together START/STOP button and DOWN button and give power supply. Release the buttons after 5
seconds.
It is then possible to enable the BTLE connection by removing power supply, wait at least 30 seconds till the red STAND-BY
led is OFF, keep pressed together START/STOP button and UP button and give power supply. Release the buttons after 5
seconds.
Through the App it is possible to:
Monitor multiple operating parameters simultaneously.
Get statistics of energy consumption and check alarms history.
Perform reports with the possibility to insert notes, images and email them or keep them into the digital archive.
Make programs, save them in the archive, copy them to other devices and share them among multiple users.
Remotely control, via wi-fi or GSM, a device, using a smartphone nearby as a modem.
Access to manuals and additional documentation.
Have on-line help on parameters and alarms details.
5.1.1 Monitoring
Following parameters can be monitored through the App in “Monitor” selection.
Actual value [bar]
Actual value is the value read by the sensor.
Set value [bar]
Set value is the value which has to be kept constant.
Frequency [Hz]
Motor running frequency.
Voltage Bus DC [V]
DC voltage on capacitor bus.
Motor current [A]
Phase current absorbed by the motor.
Motor power factor
Motor cosphi (P.F.).
Power [W]
Electrical power absorbed by the motor.
Module temperature [°C]
IGBT module temperature.
PCB temperature [°C]
Printed circuit board temperature.
Inverter hours [h]
Total inverter hours.
Motor hours [h]
Total motor running hours.
Address
Unit address when in COMBO mode.
ALARM HISTORY
Record of last 8 alarms.