SSFD
FreqStart;
FreqStop;
FreqStep;
Detector;
HoldTime; Rbw;
MinAtt; Preamp;
Preselector;
ScanHoldT
•
Preamp.
This Parameter switches the Preamplifier On or Off according to
its content as follows.
o
On
. It turns ON the preamplifiaer.
o
Off.
It turns Off the preamplifiaer.
•
Preselector.
This Parameter switches the Preselector On or Off according
to its content as follows.
o
On
. It turns ON the Preselector.
o
Off.
It turns Off the Preselector.
•
ScanHoldT
= Hold Time used in Smart Mode when tuning for Peak for each
step and it is expressed in ms. Note that this is used only in case of Smart
Mode and not in standard sweep. This parameters is not compulsory and
can be omitted if not required. I case it is not present, minimum time is
taken.
This command triggers a free sweep (no automatic items are selected) based on the
provided parameters. After this command has been received, all parameters issued
in the command itself are checked out and, if coherent, a sweep starts otherwise the
related error is notified and the sweep is not triggered.
Moreover, using the Frequency-Scan-Tab, the user has the capability of tuning only
those frequencies which are suspected skipping thus the remainder. Hence, saving
a lot of time.
After the command has been received, the 7010 replies by sending a string which
reflects the status of parameter check as follows:
•
SFD=OK
<RC><LF> No error in parameters and sweep started.
•
SFD=ERR 1
<RC><LF> An Error was found in
start
or
stop
frequencies.
Errors can be one of the following:
o
Start Frequency lower than minimum allowed frequency
o
Stop Frequency higher than maximun allowed frequency
o
Start Frequency higher than Stop Frequency
•
SFD=ERR 2
<RC><LF> An Error was found in
step
frequency. Step is either
o
Too
small.
o
Is equal to zero (use of Frequency-Scan-Tab) but there are less than two
frequencies in the table
•
SFD=ERR 3
<RC><LF> An Error was found in
detector
. Errors can be one of
the following:
o
Invalid Detector or no detector found. Detectors must be indicated by
‘P’,’Q’,’R’,’A’,’N’
and
‘S
’ only
o
Smart Mode selected but no active limit
o
Smart Mode selected but no alternative detector
o
Smart Mode selected but more than two alternative detector indicated
•
SFD=ERR 4
<RC><LF> An Error was found in
HoldTime
value.
HoldTime
is
either too big (>10s) or negative.
•
SFD=ERR 5
<RC><LF> An Error was found in
RBW
. Errors can be one of the
following:
o
Unsuitable RBW for the active unit (for instance 200HZ Rbw while
Downconverter is active)
o
Unsuitable RBW for the detector previously selected (for instance 100kHZ
Rbw and QuasiPeak selected).
•
SFD=ERR 6
<RC><LF> An Error was found in
MinAtt
value. Errors can be one
of the following:
o
MinAtt
value is negative
o
MinAtt
value is higher than maximum available attenuation
o
MinAtt
value is not in step of 5
•
SFD=ERR 7
<RC><LF> An Error was found in
Preamp
string.
Preamp
string
can be either
ON
or
OFF
only. String is not case sensitive.
•
SFD=ERR 8
<RC><LF> An Error was found in
Preselector
string.
Preselector
string can be either
ON
or
OFF
only. String is not case sensitive.
Summary of Contents for PMM 7010 Series
Page 8: ...VIII Contents This page has been left blank intentionally...
Page 36: ...4 6 Applications This page has been left blank intentionally...
Page 50: ...6 8 PMM 9010 RMA Rack Mount Adapter This page has been left blank intentionally...
Page 76: ...Suggerimenti Commenti Note Suggestions Comments Note...