7-2
Remote control
7.5 List of
commands
Query
COMMANDs
Syntax Function
?3PR*
Tells whether the apparatus is a PMM 7010 and in which mode
?AAT*
Requests the Attenuator status for Analyzer mode.
?ACE*
Requests the Center frequency for analyzer mode
?ADT*
Requests the detector used for Analyzer mode
?AHT*
Requests the Hold Time for Analyzer mode.
?AOP*
Requests the Stop frequency for analyzer mode
?ART*
Requests the Start frequency for analyzer mode
?ASP*
Requests the Span frequency for analyzer mode
?CFA*
Sends back the ID of the conversion factor
?CRA*
Tells whether RMS-AVG detector is available
?DET*
Reports the five detector for manual mode
?DMD*
Requests the status of demodulator.
?DMV*
Requests the volume of demodulator.
?FPGA
Sends back a string containing information about version of FPGA.
?IDN*
Requests model, release and date of firmware
?LSN
Sends back a string showing which Band B input is selected
?MAF*
Requests the tuning frequency for manual mode
?MAT*
Requests the Attenuator status for Manual mode
?MHT*
Requests the Hold Time for manual mode
?RBW
Sends back a string expressing the selected RBW
?S/N*
Requests Serial Number internally stored by manufacturer
?TAT*
Requests the MinAtt value
?TMP
Sends back a string showing the temperature expressed in
Celsius
(°C)
?UHT*
Requests the actual Hold Time currently or lastly used
?UPP*
Requests the status of input PINs of the User Port
Summary of Contents for PMM 7010 Series
Page 8: ...VIII Contents This page has been left blank intentionally...
Page 36: ...4 6 Applications This page has been left blank intentionally...
Page 50: ...6 8 PMM 9010 RMA Rack Mount Adapter This page has been left blank intentionally...
Page 76: ...Suggerimenti Commenti Note Suggestions Comments Note...