background image

20

W415-0619 / B / 03.03.08

PART NO.  DESCRIPTION

 

W225-0216 

DOOR FRAME  

2* W562-0008 

DOOR 

GASKET

3* 

W010-1736 

DOOR LATCH ASSEMBLY  

4 W010-1743 

GLASS 

C

/

W

 GASKET

5* W300-0088 

GLASS

6 W100-0104 

BURNER 

 

7 W357-0006 

IGNITOR

8 W190-0026 

CONTROL, 

MODULE

9* W750-0183 

WIRE 

HARNESS

10* W750-0184 

IGNITION 

CABLE

11 W200-0234 

IGNITOR 

COVER

12 W200-0233 

BURNER 

COVER

13 

W725-0052 

NATURAL GAS VALVE - 3.5” W.C. 

13 

W725-0053 

PROPANE GAS VALVE - 10.0” W.C.

14* 

W455-0085 

NATURAL GAS ORIFICE

14* 

W455-0086 

PROPANE GAS ORIFICE 

15 W500-0358 

FIRESTOP 

SPACER

16 W475-0522 

BACK 

PANEL

17* W300-0108 

ACCENT 

GLASS 

(

BLACK

)

18* W385-0334 

NAPOLEON® 

LOGO

19 W290-0123 

EXHAUST 

GASKET

20 W290-0125 

BURNER 

GASKET

21* 

W562-0046 

ROPE GASKET, BACK PANEL

22 TFK 

 FRAME - 

PAINTED

 

METAILIC

 

BLACK

 

FINISH

22 TFR 

 FRAME - 

RED

 

FINISH

22 TFP 

 FRAME - 

PEWTER

 

FINISH

22 TFW 

 FRAME - 

WHITE

 

FINISH

22 

TFB 

 FRAME - 

STEEL

 

BLUE

 

FINISH

35* W573-0002 

HIGH 

TEMPERATURE 

SEALANT

35* W573-0007 

HIGH 

TEMPERATURE 

SEALANT 

36* W175-0204 

3” 

COUPLER

37* W175-0166 

5” 

COUPLER 

 

38*  W175-0270 

CONVERSION KIT - 

NG

 

TO

 

LP

39*  W175-0274  

CONVERSION KIT - 

LP

 

TO

 

NG

40* W175-0271 

COUPLER 

KIT

41* LK8 

LIGHT 

KIT

42* AVS35KT 

VENT 

SLEEVE 

ASSEMBLY

Contact your dealer for questions concerning prices and availability 
of replacement parts. Normally all parts can be ordered through your 
Napoleon® dealer or distributor. 
When ordering replacement parts always give the following 
information:

1.  

MODEL

 &

 

SERIAL

 

NUMBER

 

OF

 

FIREPLACE

2.  

INSTALLATION

 

DATE

 

OF

 

FIREPLACE

 

3.  

PART

 

NUMBER

 

4.  

DESCRIPTION

 

OF

 

PART

 

5.  

FINISH

FOR

 

WARRANTY

 

REPLACEMENT

 

PARTS

A

 

PHOTOCOPY

 

OF

 

THE

 

ORIGINAL

 

INVOICE

 

WILL

 

BE

 

REQUIRED

 

TO

 

HONOUR

 

THE

 

CLAIM

.

IDENTIFIES

 

ITEMS

 

WHICH

 

ARE

 

NOT

 

ILLUSTRATED

FOR

 

FURTHER

 

INFORMATION

CONTACT

 

YOUR

 

NAPOLEON

® 

DEALER

.

REPLACEMENTS

REPLACEMENT PARTS

ACCESSORIES

GD178 (WALL TERMINAL KIT)

28* 

W010-1744 

12” FLEXIBLE VENT ASSEMBLY

29 

W670-0010 

3”/5” FLEXIBLE HORIZONTAL TERMINAL

GD179 (TERMINAL ONLY)

29 

W670-0010 

3”/5” FLEXIBLE HORIZONTAL TERMINAL

FLEXIBLE VENT KITS

TERMINAL KITS

GDT5 (5 FT)

23* 

W730-0031 

3” FLEXIBLE VENT PIPE - (5 

FT

24* 

W730-0032 

5” FLEXIBLE VENT PIPE - (5 

FT

)

25* W615-0080 

SPACERS 

(3 

INCLUDED

)

GDT10 (10 FT)

26* 

W730-0033 

3” FLEXIBLE VENT PIPE - (10 

FT

)

27* 

W730-0034 

5” FLEXIBLE VENT PIPE - (10 

FT

)

25* W615-0080 

SPACERS 

(6 

INCLUDED

)

1

4

16

6

7

8

11

12

13

15

19

20

29

22

ROOF TERMINAL KITS

GDT113 

30* W670-0011 

AIR 

TERMINAL

31* 

W490-0076 

3/5 INNER/OUTER SLEEVE

GDT110 (1/12 - 7/12 PITCH)

30* W670-0011 

AIR 

TERMINAL

31* 

W490-0076 

3/5 INNER/OUTER SLEEVE 

 

32* W010-1844 

ROOF 

SUPPORT

33* W263-0099 

ROOF 

FLASHING 

34* W170-0134 

STORM 

COLLAR

GDT111 (8/12 - 12/12 PITCH)

30* W670-0011 

AIR 

TERMINAL

31* 

W490-0076 

3/5 INNER/OUTER SLEEVE 

 

32* W010-1844 

ROOF 

SUPPORT

33* W263-0100 

ROOF 

FLASHING 

34* W170-0134 

STORM 

COLLAR

GDT112 (FLAT ROOF)

30* W670-0011 

AIR 

TERMINAL

31* 

W490-0076 

3/5 INNER/OUTER SLEEVE 

 

32* W010-1844 

ROOF 

SUPPORT

33* W263-0101 

ROOF 

FLASHING 

34* W170-0134 

STORM 

COLLAR

Failure to position the parts in accordance with these diagrams or 

failure to use only parts specified approved with this appliance may 

result in property damage or personal injury.

!

WARNING

Summary of Contents for TORCH GT8P

Page 1: ...y appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot re...

Page 2: ...erials gasoline and other flammable vapours and liquids Under no circumstances should this fireplace be modified This fireplace must not be connected to a chimney flue pipe serving a separate solid fu...

Page 3: ...ents and wearable parts such as blowers gas valves thermal switch switches wiring remote controls ignitor gasketing and pilot assembly are covered and NAPOLEON will provide replacement parts free of c...

Page 4: ...on carpeting vinyl tile or other combustible material other than wood flooring the fireplace shall be installed on a metal or wood panel extending the full width and depth GENERAL INSTRUCTIONS GENERA...

Page 5: ...als on the inner exhaust flue only the outer air intake joints must be sealed using a red high temperature silicone RTV This same sealant may be used on both the inner exhaust and outer intake vent pi...

Page 6: ...ated with the insulation wrapped in a protective sleeve to minimize condensation Provide a means for visually checking the vent connection to the fireplace after the fireplace is installed Use firesto...

Page 7: ...24 2a Horizontal run if vent run includes vertical rise 4 7 FT 2b Vertical run Immediately off the fireplace if 7 FT maximum horizontal run is required 18 7 FT 2b 2c FIGURE 2a 4 MIN 24 MAX 8 18 MAXIMU...

Page 8: ...excluding fireplace and air terminal connections N A 2 Rise per foot recommended 1 4 N A Rise per foot allowable 0 N A Vertical run when not venting horizontally 24 19 1 2 FT 3a 3c Horizontal run 4 5...

Page 9: ...9 W415 0619 B 03 03 08 O O B B G A F C H H L K J M MINIMUM AIR TERNMINAL LOCATION CLEARANCES N D E O FIGURE 4...

Page 10: ...g to cut them Use a plumb bob to line up the center of the openings Do not fill this space with any type of material A vent pipe shield will prevent any materials such as insulation from filling up th...

Page 11: ...e joints may be sealed using high temperature sealant W573 0002 not supplied or the high temperature sealant W573 0007 Mill Pac not supplied However the high temperature sealant W573 0007 Mill Pac not...

Page 12: ...ed Conversion Kits The mobile home appliance is field convertible between Natural Gas NG and Propane LP To convert from one gas to another consult your Napoleon dealer distributor FIGURE 14 STORM COLL...

Page 13: ...18 WARNING RISK OF ELECTRIC SHOCK Control and valve operate with 110v 1 2 3 4 YELLOW BROWN W H I T E P U R P L E B L A C K IGNITOR WIRE IGNITOR GAS VALVE SWITCH CONTROL MODULE GROUND 110v POWER SUPPL...

Page 14: ...s installed Frame to local building codes To install the fireplace face flush with the finished surface position the framework to accommodate the thickness of the finished surface Use 4 flat head scre...

Page 15: ...from the slots in the door frame to release the top of the door Then pivot forward until the top edge of the door clears the front of the fireplace Next gripping the sides of the door lift the door ou...

Page 16: ...7 Once the frame is perfectly square and the control door will close without rubbing against the sides of the frame tighten all screws 8 Open the control door 9 Insert the door stop chain into the re...

Page 17: ...res into the clips at both sides and the bottom of the frame Use the extra clips provided to retain any loose wires 7 Re attach frame onto unit 8 Remove the control panel by removing the 2 screws secu...

Page 18: ...2 Turn off all electrical power to the fireplace if service is to be preformed 3 Turn manual shut off valve clockwise to off Do not force TO TURN OFF GAS CERTIFIED UNDER CSA 2 22 2007 ANSI 21 50 2007...

Page 19: ...pressure FIGURE 34 FIGURE 33 TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause imprope...

Page 20: ...LACE 2 INSTALLATION DATE OF FIREPLACE 3 PART NUMBER 4 DESCRIPTION OF PART 5 FINISH FOR WARRANTY REPLACEMENT PARTS A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM IDENTIFIES IT...

Page 21: ...issing and that the seal is tight Check that both 3 and 5 vent liners are free of holes and well sealed at all joints Check that the minimum rise per foot has been adhered to for any horizontal ventin...

Page 22: ...22 W415 0619 B 03 03 08 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS...

Reviews: