background image

18

W415-0619 / B / 03.03.08

A.

  This 

fi

 replace is equipped with an ignition device which 

automatically lights the burner.  Do not try to light by hand.

B.

  Before operating, smell all around the 

fi

 replace area for 

gas and next to the 

fl

 oor because some gas is heavier than 

air and will settle on the 

fl

 oor.

C. 

 Do not use this 

fi

 replace if any part has been under water. 

Immediately call a quali

fi

 ed service technician to inspect the 

fi

 replace and replace any part of the control system  and any 

gas control which has been under water.

When lit for the 

fi

 rst time, the 

fi

 replace will emit a slight odour for 

a few hours. This is a normal temporary condition caused by the 
curing of paints and lubricants used in the manufacturing process 
and will not occur again. Simply open a window to suf

fi

 ciently 

ventilate the room.
After extended periods of non-operation such as following a 
vacation or a warm weather season, the 

fi

 replace may emit a 

•  Turn off all gas to the 

fi

 replace.

• Open 

windows. 

•  Do not try to light any appliance. 
•  Do not touch any electrical switch; do not use any phone in  
 your 

building.

•  Immediately call your gas supplier from a neighbor’s    
phone.  Follow the gas supplier’s instructions.
•  If you cannot reach your gas supplier, call the 

fi

 re  

 

 department. 

1.

  

STOP!  

Read the safety information located above.

2.

  Turn off all electric power to the 

fi

 replace.

3.

  This 

fi

 replace is equipped with an ignition device which 

automatically lights the burner.  Do not try to light by hand.

4.  

Remove the glass door.

5. 

 Wait 

fi

 ve (5) minutes to clear out any gas.  If you smell gas 

including near the 

fl

 oor STOP!  Follow “B” in the above safety 

information on this label.  If you don’t smell gas go to the next 
step.

6. 

 Replace the glass door.

7.

  Turn on all electric power to the 

fi

 replace.

8. 

 Turn the 

fi

 replace switch to the ON position.

9.  

If 

fi

 replace will not operate, follow instructions “To Turn Off 

Gas” and call your service technician or gas supplier.

FOR YOUR SAFETY READ BEFORE LIGHTING:

LIGHTING INSTRUCTIONS

WHAT TO DO IF YOU SMELL GAS:

FIGURE 32

slight odour for a few hours. This is caused by dust particles in 
the heat exchanger burning off. Open a window to suf

fi

 ciently 

ventilate the room.

Purge all gas lines with the glass door of the 

fi

 replace open. 

Assure that a continuous gas 

fl

 ow is at the burner before 

closing the door.

OPERATING INSTRUCTIONS

1. 

Turn the 

fi

 replace switch to the OFF position.

2.

 Turn off all electrical power to the 

fi

 replace if service is to 

be preformed.

3.

 Turn manual shut-off valve clockwise to 

off.  

    Do not force.

TO TURN OFF GAS

CERTIFIED UNDER : CSA 2.22-2007, ANSI 21.50-2007 VENTED GAS FIREPLACE

DIRECT VENT GAS FIREPLACE. APPROVED FOR BEDROOM, BATHROOM AND BED SITTING ROOM INSTALLATION. 
SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA 
Z240MH SERIES GAS EQUIPPED MOBILE HOMES. IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME 
CONSTRUCTION AND SAFETY STANDARD. TITLE 24 DFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE 
THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, 
ANSI/NFPA 501A.

INT

ERTEK

W

arn

ock Her

se

y

CM

C

US

ALTITUDE

INPUT

ORIFICE

MANIFOLD PRESSURE:

3.5" WATER COLUMN

MINIMUM SUPPLY PRESSURE:

4.5" WATER COLUMN

MAXIMUM SUPPLY PRESSURE:

7.0" WATER COLUMN

MANIFOLD PRESSURE:

10" WATER COLUMN

MINIMUM SUPPLY PRESSURE:

11" WATER COLUMN

MAXIMUM SUPPLY PRESSURE:

13" WATER COLUMN

0-4500FT (0-1370m)
6,000 BTU/h

#69

0-4500FT (0-1370m)

6,000 BTU/h

#56

CERTIFIED FOR CANADA AND USA

GT8N

MODEL

GT8P

MODEL

W385-0381 / A

GT8

VENTED GAS FIREPLACE NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS
DOOR. CERTIFIED WITH THIS UNIT ONLY.

WARNING:

DO NOT ADD ANY MATERIAL TO THE 

APPLIANCE, WHICH WILL COME IN CONTACT WITH 
THE FLAMES, OTHER THAN THAT SUPPLIED BY THE 
MANUFACTURER WITH THE APPLIANCE.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
TOP 6” 

RECESSED 

DEPTH 

7” 

FLOOR 0” 

VENT   

1”

SIDES 0” 

BACK   

1/2”

MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS 
            ARE 10 INCHES AND 10 FEET RESPECTIVELY. 
            MINIMUM AND MAXIMUM VERTICAL VENT LENGTHS 
            ARE 36 INCHES AND 10 FEET RESPECTIVELY. 

MADE IN CANADA

WOLF STEEL LTD, BARRIE, ON, CANADA

SERIAL NUMBER:

THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT 
KITS, SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER 
REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE 
VENT-AIR INTAKE SYSTEM.

ELECTRICAL RATING: 115v 0.82AMP, 60HZ

REFERENCE #15901

TOP, SIDES & BACK AS PER ABOVE. FOR FINISHING
MATERIAL, SEE OWNERS MANUAL.

(NATURAL GAS)

(PROPANE)

THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE 
RATING PLATE AND MY BE INSTALLED IN AN AFTERMARKET, PERMANENTLY 
LOCATED, MANUFACTURED HOME (USA ONLY) OR MOBILE HOME WHERE NOT 
PROHIBITED BY LOCAL CODES. SEE OWNER’S MANUAL FOR DETAILS. THIS 
APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES, UNLESS A 
CERTIFIED KIT IS USED.

RATING PLATE

RATING LABEL LOCATION: The rating label is located under the control panel and is chained to the 

fi

 replace.  

DO NOT REMOVE.

Summary of Contents for TORCH GT8P

Page 1: ...y appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot re...

Page 2: ...erials gasoline and other flammable vapours and liquids Under no circumstances should this fireplace be modified This fireplace must not be connected to a chimney flue pipe serving a separate solid fu...

Page 3: ...ents and wearable parts such as blowers gas valves thermal switch switches wiring remote controls ignitor gasketing and pilot assembly are covered and NAPOLEON will provide replacement parts free of c...

Page 4: ...on carpeting vinyl tile or other combustible material other than wood flooring the fireplace shall be installed on a metal or wood panel extending the full width and depth GENERAL INSTRUCTIONS GENERA...

Page 5: ...als on the inner exhaust flue only the outer air intake joints must be sealed using a red high temperature silicone RTV This same sealant may be used on both the inner exhaust and outer intake vent pi...

Page 6: ...ated with the insulation wrapped in a protective sleeve to minimize condensation Provide a means for visually checking the vent connection to the fireplace after the fireplace is installed Use firesto...

Page 7: ...24 2a Horizontal run if vent run includes vertical rise 4 7 FT 2b Vertical run Immediately off the fireplace if 7 FT maximum horizontal run is required 18 7 FT 2b 2c FIGURE 2a 4 MIN 24 MAX 8 18 MAXIMU...

Page 8: ...excluding fireplace and air terminal connections N A 2 Rise per foot recommended 1 4 N A Rise per foot allowable 0 N A Vertical run when not venting horizontally 24 19 1 2 FT 3a 3c Horizontal run 4 5...

Page 9: ...9 W415 0619 B 03 03 08 O O B B G A F C H H L K J M MINIMUM AIR TERNMINAL LOCATION CLEARANCES N D E O FIGURE 4...

Page 10: ...g to cut them Use a plumb bob to line up the center of the openings Do not fill this space with any type of material A vent pipe shield will prevent any materials such as insulation from filling up th...

Page 11: ...e joints may be sealed using high temperature sealant W573 0002 not supplied or the high temperature sealant W573 0007 Mill Pac not supplied However the high temperature sealant W573 0007 Mill Pac not...

Page 12: ...ed Conversion Kits The mobile home appliance is field convertible between Natural Gas NG and Propane LP To convert from one gas to another consult your Napoleon dealer distributor FIGURE 14 STORM COLL...

Page 13: ...18 WARNING RISK OF ELECTRIC SHOCK Control and valve operate with 110v 1 2 3 4 YELLOW BROWN W H I T E P U R P L E B L A C K IGNITOR WIRE IGNITOR GAS VALVE SWITCH CONTROL MODULE GROUND 110v POWER SUPPL...

Page 14: ...s installed Frame to local building codes To install the fireplace face flush with the finished surface position the framework to accommodate the thickness of the finished surface Use 4 flat head scre...

Page 15: ...from the slots in the door frame to release the top of the door Then pivot forward until the top edge of the door clears the front of the fireplace Next gripping the sides of the door lift the door ou...

Page 16: ...7 Once the frame is perfectly square and the control door will close without rubbing against the sides of the frame tighten all screws 8 Open the control door 9 Insert the door stop chain into the re...

Page 17: ...res into the clips at both sides and the bottom of the frame Use the extra clips provided to retain any loose wires 7 Re attach frame onto unit 8 Remove the control panel by removing the 2 screws secu...

Page 18: ...2 Turn off all electrical power to the fireplace if service is to be preformed 3 Turn manual shut off valve clockwise to off Do not force TO TURN OFF GAS CERTIFIED UNDER CSA 2 22 2007 ANSI 21 50 2007...

Page 19: ...pressure FIGURE 34 FIGURE 33 TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause imprope...

Page 20: ...LACE 2 INSTALLATION DATE OF FIREPLACE 3 PART NUMBER 4 DESCRIPTION OF PART 5 FINISH FOR WARRANTY REPLACEMENT PARTS A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM IDENTIFIES IT...

Page 21: ...issing and that the seal is tight Check that both 3 and 5 vent liners are free of holes and well sealed at all joints Check that the minimum rise per foot has been adhered to for any horizontal ventin...

Page 22: ...22 W415 0619 B 03 03 08 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS...