background image

15

W415-0619 / B / 03.03.08

2” MIN.*

12”

MIN. TO

COMBUSTIBLES

(to ceiling or mantle)

1

1

/

2

” MIN.

* Any protruding finishing 

material installed in this 

space (ie. baseboards) 

must leave 2” of 

unobstructed clearance to 

allow for full rotation of the 

control door.

COMBUSTIBLE

NON-COMBUSTIBLE

1”

1”

0” IF 
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK AN
STONE.

BRICK

6”
MIN.

FIGURE 23

CLEARANCES TO COMBUSTIBLES

Minimum clearance to combustible construction from 

fi

 replace and vent surfaces:

Fireplace framing:   -  6” to top
 

-  0” to stand-offs 

 

  (rear and sides)

Vent pipe: 

-  1” 

Recessed depth: 

-  7”

Before the glass door can be removed, the optional frame/
front must be removed.
The glass door is secured to the top front edge of the 

fi

 rebox. 

Pull the handles of the latches forward, then lift the hooks out 
from the slots in the door frame to release the top of the door. 
Then, pivot forward until the top edge of the door clears the 
front of the 

fi

 replace.  Next gripping the sides of the door lift 

the door out from the retainer along the bottom of the door. 

DOOR REMOVAL

FINISHING

OPEN

CLOSED

GLASS REMOVAL

Having removed the door, lay on a smooth 

fl

 at surface, face 

down.  There are 4 glass retainers that need to be bent away 
from the glass to release it from the frame.  Do not pry on 
the glass.
When replacing 

DO NOT SUBSTITUTE MATERIAL

, replace 

the gasket (W562-0008) and the glass (W300-0088).  Set 
new glass into the frame and gently bend tabs into the 
gasket to secure.

NOTE:

 Care must be taken when removing and disposing 

of any broken glass or damaged components. Be sure to 
vacuum up any broken glass from inside the 

fi

 replace before 

operation.

FIGURE 24

GLASS

RETAINERS

GASKET

GLASS

FIGURE 25

FRAME

CONTROL DOOR 

(OPEN POSITION)

WITHOUT 

 FRAME INSTALLED

WITH                    FRAME INSTALLED

Summary of Contents for TORCH GT8P

Page 1: ...y appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot re...

Page 2: ...erials gasoline and other flammable vapours and liquids Under no circumstances should this fireplace be modified This fireplace must not be connected to a chimney flue pipe serving a separate solid fu...

Page 3: ...ents and wearable parts such as blowers gas valves thermal switch switches wiring remote controls ignitor gasketing and pilot assembly are covered and NAPOLEON will provide replacement parts free of c...

Page 4: ...on carpeting vinyl tile or other combustible material other than wood flooring the fireplace shall be installed on a metal or wood panel extending the full width and depth GENERAL INSTRUCTIONS GENERA...

Page 5: ...als on the inner exhaust flue only the outer air intake joints must be sealed using a red high temperature silicone RTV This same sealant may be used on both the inner exhaust and outer intake vent pi...

Page 6: ...ated with the insulation wrapped in a protective sleeve to minimize condensation Provide a means for visually checking the vent connection to the fireplace after the fireplace is installed Use firesto...

Page 7: ...24 2a Horizontal run if vent run includes vertical rise 4 7 FT 2b Vertical run Immediately off the fireplace if 7 FT maximum horizontal run is required 18 7 FT 2b 2c FIGURE 2a 4 MIN 24 MAX 8 18 MAXIMU...

Page 8: ...excluding fireplace and air terminal connections N A 2 Rise per foot recommended 1 4 N A Rise per foot allowable 0 N A Vertical run when not venting horizontally 24 19 1 2 FT 3a 3c Horizontal run 4 5...

Page 9: ...9 W415 0619 B 03 03 08 O O B B G A F C H H L K J M MINIMUM AIR TERNMINAL LOCATION CLEARANCES N D E O FIGURE 4...

Page 10: ...g to cut them Use a plumb bob to line up the center of the openings Do not fill this space with any type of material A vent pipe shield will prevent any materials such as insulation from filling up th...

Page 11: ...e joints may be sealed using high temperature sealant W573 0002 not supplied or the high temperature sealant W573 0007 Mill Pac not supplied However the high temperature sealant W573 0007 Mill Pac not...

Page 12: ...ed Conversion Kits The mobile home appliance is field convertible between Natural Gas NG and Propane LP To convert from one gas to another consult your Napoleon dealer distributor FIGURE 14 STORM COLL...

Page 13: ...18 WARNING RISK OF ELECTRIC SHOCK Control and valve operate with 110v 1 2 3 4 YELLOW BROWN W H I T E P U R P L E B L A C K IGNITOR WIRE IGNITOR GAS VALVE SWITCH CONTROL MODULE GROUND 110v POWER SUPPL...

Page 14: ...s installed Frame to local building codes To install the fireplace face flush with the finished surface position the framework to accommodate the thickness of the finished surface Use 4 flat head scre...

Page 15: ...from the slots in the door frame to release the top of the door Then pivot forward until the top edge of the door clears the front of the fireplace Next gripping the sides of the door lift the door ou...

Page 16: ...7 Once the frame is perfectly square and the control door will close without rubbing against the sides of the frame tighten all screws 8 Open the control door 9 Insert the door stop chain into the re...

Page 17: ...res into the clips at both sides and the bottom of the frame Use the extra clips provided to retain any loose wires 7 Re attach frame onto unit 8 Remove the control panel by removing the 2 screws secu...

Page 18: ...2 Turn off all electrical power to the fireplace if service is to be preformed 3 Turn manual shut off valve clockwise to off Do not force TO TURN OFF GAS CERTIFIED UNDER CSA 2 22 2007 ANSI 21 50 2007...

Page 19: ...pressure FIGURE 34 FIGURE 33 TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause imprope...

Page 20: ...LACE 2 INSTALLATION DATE OF FIREPLACE 3 PART NUMBER 4 DESCRIPTION OF PART 5 FINISH FOR WARRANTY REPLACEMENT PARTS A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM IDENTIFIES IT...

Page 21: ...issing and that the seal is tight Check that both 3 and 5 vent liners are free of holes and well sealed at all joints Check that the minimum rise per foot has been adhered to for any horizontal ventin...

Page 22: ...22 W415 0619 B 03 03 08 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS...

Reviews: