EN
W415-2341 / A / 11.14.19
5
standard checklist
1.0 general information
note:
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
Installer, please fi ll out the following information:
Customer:
________________________________________________________________________
Address: ________________________________________________________________________
Date of Installation:
________________________________________________________________________
Location of Appliance:
________________________________________________________________________
Installer:
________________________________________________________________________
Dealer/Distributor contact number: ________________________________________________________________________
Serial
#:
________________________________________________________________________
Model:
Natural Gas:
GI3600-4NSB
Propane:
GI3600-4PSB
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appli-
ance and must be installed.
No external electricity (110 volts or 24 volts) is required for the gas system operation.
Under extreme vent confi gurations, allow several minutes (5-15) for the fl ame to stabilize after ignition.
Altitudes greater than 4000ft (1219m) require a minimum vent run of 12ft (4m).
When the appliance is installed at elevations above 4,500ft (1372m), and in the absense of specifi c
recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m).
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is not approved for closet or recessed installations. It is approved for bathroom, bedroom and bed-sitting
room installations.
1.1
rates and effi ciencies
RATES AND EFFICIENCIES
NG
P
Max. Input (BTU/HR)
24,000
22,000
Max. Output (BTU/HR)
15,900
16,000
Min. Inlet Gas Supply Pressure
4.5" (11mb) Water Column
11" (27mb) Water Column
Max. Inlet Gas Supply Pressure
7"* (17mb) Water Column
13" (34mb) Water Column
Manifold Pressure (Under Flow Conditions)
3.5" (9mb) Water Column
10" (25mb) Water Column
* Maximum inlet pressure not to exceed 13".