troubleshooting
symptom
problem
test solution
Lights or blower
won’t function (if
equipped).
Control module switch in
wrong position.
-
Verify ON/OFF switch is in the “I” position which denotes on.
COM switch is unplugged.
-
Verify “COM” switch is plugged into the front of the control
module.
Flames are very
aggressive.
Door is ajar.
-
Ensure door is secured properly.
Venting action is too great.
-
Check to ensure venting is properly sealed or restrict vent
exit with restrictor plate. (Not available in all appliances).
Appliance won’t per-
form any functions.
No power to the system.
-
Check breaker to verify it’s in the “
on
” position.
Receiver switch in wrong
position (if equipped).
-
Verify that the 3 position switch on the receiver is in the
remote position (middle).
Transmitter isn’t operational.
-
Check battery power and battery orientation.