W415-2341 / A / 11.14.19
EN
16
operation
5.3 fl ame characteristics
5.4 blower
replacement
This appliance comes standard with a blower, a heat sensor, variable on/off speed control and a power cord.
Because the blower is thermally activated, when turned on, it will automatically start approximately 15 minutes
after lighting the appliance and will run for approximately 30 minutes after the appliance has been turned off. Use
of the fan increases the output of heat. Air, drawn in through the lower louvre access door, is driven up the back of
the fi rebox, and exhausted as hot air between the upper louvres.
G
V
B
HEAT
VARIABLE SPEED SWITCH
FAN
SENSOR
1. Turn off the gas and electric power to the appliance.
2. Remove the safety screen and upper glass bracket. Loosen the lower glass bracket and remove the glass.
3. Remove the logs, refer to " LOG PLACEMENT" section for detailed instructions.
4. Remove the burner assembly.
5. Remove
the
eight
screws holding the access
door in place on the control assembly (located
at the back of the burner support).
6. Remove the four screws holding the blower
duct and slide it forward from beneath the
burner support.
7. Disconnect the electrical connectors at the
blower.
8. Remove the blower.
9. To reinstall the blower reverse these steps.
PILOT BURNER
THERMOPILE
ELECTRODE
It’s important to periodically perform a visual check of
the pilot and burner flames. Compare them to the
illustration provided. If any flames appear abnormal,
call a service person.
!
WARNING
• Risk of fire and electrical shock!
• Turn off the gas and electrical power before servicing this appliance.
• Use only Wolf Steel approved optional accessories and replacement parts with this appliance. Using
non-listed accessories (blowers, doors, louvres, trims, gas components, venting components, etc.) could
result in a safety hazard and will void the warranty and certification.
• Ensure that the fan’s power cord is not in contact with any surface of the appliance to prevent electrical
shock or fire damage. Do not run the power cord beneath the appliance.
• The wire harness provided in the blower kit is a universal harness. When installed, ensure that any excess
wire is contained, prevent it from making contact with moving or hot objects.
8 SCREWS
ACCESS DOOR
BLOWER
DUCT