9
SAFETY CHECKS
NOTE: Always check the following
connections.
Check all connections on the hose regulator
assembly.
Check the regulator to the LP gas cylinder
connection. Note that the regulator adapter is
a reverse thread.
Check the hose to the intake pipe to make
certain that it is not kinked or in a position that
could cause it to kink. Hand tighten and then
take a 1/2 turn with an adjustable wrench.
The remaining connections are to be tested after
this heater has been lit. (SEE LIGHTING
INSTRUCTIONS PAGE10)
Check for leaks
Your Patio Heater has been checked at all
factory connections for leaks. To check the
connection at the gas hose/regulator/cylinder:
1) Make leak solution by mixing 1part liquid
dishsoap and 3 parts water.
2) Brush solution (or use spray bottle)
onto the gas hose/regulator
and regulator/cylinder connection.
3) Turn on gas. Inspect the connections and
look for bubbles.
4) If no bubbles appear, the connection is safe.
5) If bubbles appear, there is a leak. Turn off the
gas, loosen and re-tighten this connection.
6) If leak continues call a qualified service person.
ASSEMBLY