background image

10

OPERATION

FOR YOUR  SAFETY:
If at any time you are unable to light
burner and smell gas, wait 5 minutes to
allow gas to dissipate before attempting
to light heater.
If after 1 minute you are unable to light 
burner, wait 5 minutes and allow 
flammable vapors to dissipate before
attempting to light heater again.

WARNING

FOR YOUR  SAFETY:
DO NOT touch or move heater for at least
45 minutes after use.
Allow emitter and dome to cool before 
touching. 
 

WARNING

Ignition Hole

Emitter Screen

Pus

h to

 tu

rn

OFF

H

GI

H

LO

W

TO

LI

P

Pus

h to

 tu

rn

OFF

H

GI

H

LO

W

TO

LI

P

Eletronic ignition

WARNING:

 

DO NOT attempt to operate heater until you have 

read and understand all precautions. Failure to do so can 

result in serious personal injury, death or property damage.

Before Turning Gas Supply ON

Your heater was designed and approved for OUTDOOR USE ONLY. DO NOT use it inside a
building, or any other enclosed area. Make sure surrounding areas are free of combustible
materials, gasoline and other flammable vapors or liquids. Ensure that there is no
obstruction to air ventilation. Be sure all gas connections are tight and there are no leaks.
Be sure the access panel is clear of debris. Be sure any component removed during
assembly or servicing is replaced and fastened prior to starting.

Before Lighting

Heater should be thoroughly inspected before each use, and by a qualified service person
at least annually. If relighting, always wait at least 5 minutes.

LIGHTING INSTRUCTIONS

This heater is tested for quality assurance. Ignition attempts should succeed 8 out
of 10 attempts. 

HEATER

HEATER

Note

:  If the pilot light will not ignite, turn the control knob to the off position, and fully close the 

propane tank valve or natural gas supply valve.  Wait 5 minutes and then repeat steps 2-4. 
Alternately, the pilot can be lit using a wand lighter.  Push and turn the control knob to the pilot 
position.  Depress the control knob.  Insert the lit lighter through the ignition hole on the emitter 
screen.   Once the pilot lights, remove the lighter and continue to depress the control knob for
30 seconds.
Whenever the unit is disconnected from the natural gas supply, the supply lines fill with air.  Expect
a delay in lighting the pilot, the first time the unit is lit after reconnecting.

1. Push and turn the control knob clockwise to the off position.
2. Fully open the propane tank valve or natural gas supply valve.
3. Push and turn the control knob counter-clockwise to the pilot position.  Depress the control knob.
    Push and hold the igniter button until the pilot lights.
4. Once the pilot lights, release the igniter button and continue to depress the control knob for 
    30 seconds. 
5. After depressing the control knob for 30 seconds, release the control knob and turn it 
   counter-clockwise to the low or high position.

1. Poussez et tournez le bouton de réglage vers la droite à "off". 
2. Ouvrez complètement la soupape du réservoir de propane ou de l'approvisionnement en
    gaz naturel. 
3. Poussez et tournez le bouton de réglage vers la gauche à "pilot". Appuyez sur le bouton
    de réglage. enfoncez et maintenez l'allumeur jusqu'à ce que la veilleuse s'allume. 
4. Une fois la veilleuse allumée, relâchez l'allumeur et continuez d'appuyer sur le bouton de
    réglage pendant 30 secondes.
5. Après avoir appuyé sur le bouton de réglage pendant 30 secondes, relâchez le bouton de
    réglage et tournez-le vers la gauche à "low" ou à "high".  

INSTRUCTIONS D’ALLUMAGE

Remarque : Si la veilleuse ne s'allume pas, tournez le bouton de réglage à "off" et fermez complètement la soupape du réservoir de propane ou de
l'approvisionnement en gaz naturel.  Attendez 5 minutes et répétez les étapes 2 à 4.  Comme autre alternative, la veilleuse peut être allumée à l'aide
d'un allumoir. poussez et tournez le bouton de réglage à "pilot". Appuyez sur le bouton de réglage. Insérez l'allumoir allumé dans l'orifice d'allumage 
sur l'émetteur grillagé. Lorsque la veilleuse s'allume, retirez l'allumoir et continuez d'appuyer sur le bouton de réglage pendant 30 secondes.
lorsque l'appareil est débranché du réservoir de propane ou de l'approvisionnement en gaz naturel, les conduites d'alimentation se remplissent d'air. 
Un délai sera nécessaire pour allumer la veilleuse la première fois que l'appareil sera allumé après avoir été rebranché.

Summary of Contents for PTHC38PK

Page 1: ... continues immediately call gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance WARNING For Outdoor Use Only CAUTION Retain these instructions for future use CERTIFIED I S G E N D C D E E R I T F I Model No SRPH01 Master Contract No 217109 Customer Item No PTHC38PK ...

Page 2: ... injury death or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space such as a camper tent car or home The bill of sale or copy will be re...

Page 3: ...ad Assembly 3 M6 X 70mm Double Pointed Bolts 18 M6 Washers 12 M6 X10 Screws 13 11 6 7 8 11 12 9 10 13 1 Gas Hose 1 Post 1 Gas Cylinder Housing 4 M8 X 35mm Bolts 4 M8 Lock Washers 15 M6 Nuts 4 M8 Nuts 14 15 1 Regulator 1 Cylinder Not Supplied 8 11 12 10 13 14 7 9 7 1 2 3 9 ...

Page 4: ...ts should be aware of the hazards of high surface temperature Young children should be carefully supervised when they are in the area of the heater Clothing or other flammable material should not be hung from the heater or placed on or near the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and cleaning may be required at least...

Page 5: ... For Installing Battery Remove igniter button by turning counter clockwise Install AAA battery with positive terminal up as indicated in diagram Replace igniter button Ignition button Replace Battery Control knob Ignition button AA battery 5 ...

Page 6: ... cylinder housing using the four 4 pcs Step 1 M8 35mm Bolts 8mm Lock Washer Nuts for M8 35mm Bolts 5 12 10 X X 6 Slide the gas hose with the attached Head assembly through the top of the post and down through the hole in the top of the gas cylinder housing Screw the head assembly on to the post and tighten securely 3 4 5 Step 2 8 Step 1 Attach Post to Gas Cylinder Housing Step 2 Attach Head Assemb...

Page 7: ...nter Reflector to Reflector Attach center reflector to the top of reflector 4 pcs with M6 X 10 mm screws 12 pcs Step 4 2 1 11 6mm washers 12 pcs and nuts 12 pcs 7 9 Step 3 Attach Double Threaded Bolt to Attach double threaded bolts 3 pcs and 6mm washers 3 pcs to the top of head assembly and tighten the bolts securely Head Assembly Step 3 9 13 3 ...

Page 8: ...of Head Assembly 6mm washers 3 pcs and nuts 3 pcs 7 9 13 NOTE Assembly of this heater requires basic mechanical skills Proper assembly is the responsibility of the installer Step 6 Step 6 Connect Gas Line to Cylinder Attach Gas hose to regulator hose with 3 8 Inch Open End Wrench and Adjustable Wrench Attach regulator to cylinder Tighten securely Move cylinder to the plate of base assembly 4 14 15...

Page 9: ...ted after this heater has been lit SEE LIGHTING INSTRUCTIONS PAGE10 Check for leaks Your Patio Heater has been checked at all factory connections for leaks To check the connection at the gas hose regulator cylinder 1 Make leak solution by mixing 1part liquid dishsoap and 3 parts water 2 Brush solution or use spray bottle onto the gas hose regulator and regulator cylinder connection 3 Turn on gas I...

Page 10: ...er and continue to depress the control knob for 30 seconds Whenever the unit is disconnected from the natural gas supply the supply lines fill with air Expect a delay in lighting the pilot the first time the unit is lit after reconnecting 1 Push and turn the control knob clockwise to the off position 2 Fully open the propane tank valve or natural gas supply valve 3 Push and turn the control knob c...

Page 11: ... natural gas supply valve Note After use some discoloration of the emitter screen is normal Handle with extreme care 2 1 0 P u s h t o t u r n OFF H G I H L O W T O L I P P u s h t o t u r n OFF H G I H L O W T O L I P The Event of Gas Leakage 1 Turn the control knob to OFF position 2 Wait 5 minutes to allow gas to dissipate 3 If odor continues immediately call gas supplier Operation Pressure Chec...

Page 12: ...r in the absence of local codes with the standard for the storage and handling of liquid petroleum gases ANSI NFPA 58 1986 or most recent addition For Canada with the current CAN1 B149 This heater must be placed on firm level ground Never operate in an explosive atmosphere Keep away from areas where gasoline or other flammable liquids or vapors are stored or used Figure 1 24 24 36 This heater is p...

Page 13: ...ing air passageways clean Signs of possible blockage include Gas odor with extreme yellow tipping of flame Heater does NOT reach the desired temperature Heater makes popping noises Heater glow is excessively uneven Spiders and insects can nest in burner or orifices This dangerous condition can damage heater and render it unsafe for use Clean burner holes by using a heavy duty pipe cleaner Compress...

Page 14: ...place thermocouple Gas leak in line Check connections Burner will not light Pressure is low Orifice blocked Remove clean and replace Control valve not ON Turn valve to ON Thermocouple is bad Replace thermocouple Pilot light assembly bent Place pilot in proper or not in correct location position and retry Fuel T empty Refill LP gas tank ank Lack of fuel pressure Fuel tank is near empty Supply press...