EN
W415-4001 / B / 06.15.22
5
standard checklist
Installer: please fill out appliance checklist in the
owner’s manual.
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific recommendations
from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000ft (305m). Expansion / contraction noises during heating up and cooling down cycles are normal
and are to be expected.
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is certified for mobile
home installation.
This appliance is field convertible between natural gas (NG) and propane (P). To convert from one to another,
consult your authorized dealer / distributor.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can
be improved if the assembly is warmed, using a hair dryer or similar heat source. The protective wrap must be
removed before operating the appliance.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
note:
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
Les piles doivent être mises au rebut conformément aux lois et à la réglementation locales.
Certaines piles peuvent être recyclées et acceptées dans votre centre de recyclage local. Rensei-
gnez-vous auprès de votre municipalité au sujet des directives de recyclage.
Las baterías deben desecharse de acuerdo con las leyes y regulaciones locales. Algunas baterías
pueden reciclarse, y es posible que su centro de reciclado local las acepte para desecharlas.
Consulte en su municipalidad sobre las instrucciones para el reciclado.
A barrier designed to reduce the risk of burns is provided with the appliance and must be installed. Never
operate the appliance without the barrier installed.
important:
Some components and/or media are packaged separately and must be installed in accordance with the
information in this manual.
1.0 general information
1.1 rates and efficiencies
NG
P
Altitude (FT)
0 - 4500
Max. Input (BTU/hr)
24,500
Max. Output (BTU/hr)
13,475
Min. Inlet Gas Supply Pressure
4.5" W.C. (11mb)
11" W.C. (27mb)
Max. Inlet Gas Supply Pressure
7" * W.C. (17mb)
13" W.C. (32mb)
Manifold Pressure (under Flow Conditions)
3.5 W.C. (9mb)
10" W.C. (25mb)
GDI3EA
* Max. inlet pressure not to exceed 13".