EN
W415-4001 / B / 06.15.22
27
maintenance
A.
Remove safety barrier and glass door (see "safety barrier & door removal / installation" section).
B.
Remove media tray (see "media tray installation" section) and burners.
C.
Remove porcelain radiant panels (PRPs) or brick panels (if applicable).
D.
Remove the 14 screws holding the valve train in place
(Fig. 7-2)
.
E.
Carefully lift the valve train assembly out far enough to access the manual shut off valve and turn it to the
off position. Disconnect any wires, and then lift the valve train out of the appliance.
7.6 valve train replacement
note:
A new gasket may be required when reinstalling the valve train assembly. Contact your local authorized
dealer / distributor for more information.
Fig. 7-2
GDI3EA Illustrated