4.0 VENTING
4.1 TYPE OF VENT
4.2 INSTALLING THE PELLET VENT
4.3 VENTING THE PELLET APPLIANCE
Must be an approved 3" (76mm) or 4" (102mm) diameter Type "L" or "PL" vent, vented to the outside or connect
the vent to a factory built type lined "A" chimney using an adaptor; and/or stainless steel chimney liner for
masonry appliance installations. Use 4" (102mm) diameter vent if vent or liner height is over 15' (4.5m) or if
installation is over 4,000' (1219m) above sea level.
Use an approved wall thimble when passing the vent through walls and a ceiling support / fi restop spacer when
passing the vent through ceilings (maintain a 3" (76mm) clearance to any combustibles).
7.5D
The vent must have a support bracket every 5’ (1.5m)when on
the exterior wall. To achieve optimum performance, keep vent
runs as short as possible, especially on horizontal installations.
MAXIMUM VENTING:
Maximum venting height is 33’ (10.1m)
Maximum horizontal without vertical rise is 5’ (1.5m) straight
off the back of the appliance. Use no more than 180° of
elbows (two 90° elbows, or two 45° elbows and one 90°
elbow, etc), excluding the tee and the termination.
VENT INSTALLATION:
Termination must exhaust above
the air inlet elevation, and parallel or above the exhaust
output of the pellet appliance. It is recommended that at
least 3’ (0.9m) of vertical pipe be installed to create some
natural draft. This is to help prevent the possibility of smoke
or odour entering the home during the appliance shut down
or in the event of a power outage. Horizontal sections must
have a 1/4” (6.4mm) rise every 12” (304.8mm) of travel if
longer than 3’ (0.9m).
The pellet vent connections must be sealed with HI-Temp
RTV Silicone and screwed together with at least 3 3/8”
(85.7mm) long stainless steel screws. Seal each vent
section by injecting a liberal amount of 500°F (260°C) RTV
silicone sealant into the gap. We recommend sealing the
outside of the vent connections to permit easier access
when servicing.
5’ (1.5m)
10’ (3.1m)
15’ (4.6m)
20’ (6.1m)
33’ (10.1m)
30’ (9.1m)
25’ (7.6m)
0
5’
(1.5m)
10’
(3.1m)
0
Use 4”
(101.6mm)
diameter “L”
vent if venting
in this shaded
region.
Use 3” (76.2mm)
or 4” (101.6mm)
diameter “L”
vent if venting
in this shaded
region.
!
WARNING
PELLET VENT MUST MAINTAIN A MINIMUM 3" (76.2mm) CLEARANCE TO ANY COMBUSTIBLE (INSTALL
VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER, CHIMNEY LINER EXCLUDED).
DO NOT CONNECT THE PELLET VENT TO A VENT OR CHIMNEY SERVING ANY OTHER APPLIANCE
OR HEATER.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
Summary of Contents for NPI45
Page 48: ...W415 1472 04 21 15 48 EN 67 20 29 58 41 38 43 44 63 57 60 6 11 3 NPI45 REPLACEMENT PARTS...
Page 54: ...W415 1472 04 21 15 54 EN 14 0 SERVICE HISTORY 43 1...
Page 55: ...W415 1472 04 21 15 55 EN 15 0 NOTES 44 1...
Page 106: ...106 W415 1472 04 22 15 FR 67 20 29 58 41 38 43 44 63 57 60 6 11 3 PI CES DE RECHANGE DU NPI45...
Page 114: ...114 W415 1472 04 22 15 FR 15 0 NOTES 44 1...
Page 115: ...115 W415 1472 04 22 15 FR 44 1...