5.2 MINIMUM ENCLOSURE CLEARANCES
5.3 MINIMUM CLEARANCE TO COMBUSTIBLES
!
WARNING
The stand-offs located on the back of the insert must not be removed when installing the insert into a
built-in combustible enclosure.
6”
Non-combustible
floor protection
40”
2 3/4”
7 5/8”
27”
Stand-offs
3” all around (Refer to vent
manufacturer’s instructions)
2 1/4”
6 3/8” Minimum
Side wall to appliance
8" (203mm)
Mantel to top of appliance
8" (203mm)
Top facing to appliance
6 3/8" (162mm)
Side facing to appliance
6" (152mm)
Floor protection*
6"* (152mm)
* Floor Protection: Minimum 6" (152mm)
in front of door and to either side.
8”
MIN
Side W
a
ll
8” MIN
10”
10” Mantel
6”
6”