22

W415-0210 / R / 02.27.08

FIGURE 42

GAS INSTALLATION

This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit. The fi replace is 
equipped with two 1/4" diameter holes located in the front left and right corners of the base. For mobile home installations, 
the fi replace must be fastened in place. Use #10 hex head screws, inserted through the holes in the base to secure. Always 
turn off the pilot and the fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior 
to lighting the fi replace, ensure that the logs are positioned correctly. 

MOBILE HOME INSTALLATION

Proceed once the vent installation is complete.

NOTE:  All gas connections must be contained within the fi replace when complete.

1.

 Move the fi replace into position and secure to the fl oor through the 1/4" holes located at either side of the base.

2. 

The fi replace is designed to accept 3/8" gas supply line.  The fi replace is equipped with a 3/8" manual shut-off valve.

3. 

 Connect the gas supply in accordance to local codes.  In the absence thereof, 

install according to the National Installation Code.

4. 

 When fl exing any gas line, support the gas valve so that the lines are not bent 

or kinked.

5. 

Check for gas leaks by brushing on a soap and water solution. 

DO NOT USE OPEN FLAME.

Purge all gas lines with the glass door open. Assure that a continuous gas fl ow is at the burner before closing the 

door.

 

This appliance is certifi ed to be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured 
home or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured 
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, 
CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas indicated on the rating plate. 
A conversion kit is supplied with the mobile home appliance. 

This appliance is certifi ed to be installed in an aftermarket permanently located, manufactured (mobile) home, where not 
prohibited by local codes. 

This fi replace is only for use with the type of gas indicated on the rating plate. This fi replace is not convertible for use with 
other gases, unless a certifi ed kit is used. 

For ease of accessibility, an optional remote wall switch may be installed in a 
convenient  location. A 20ft length of millivolt wire is connected to the gas valve 
and wall switch.  However, if a greater length is required route 2-strand (solid 
core) millivolt wire through the electrical hole located at the bottom left side of 
the unit. The recommended maximum lead length depends on wire size:

Attach the two leads to terminals 1 and 3 located on the gas valve.

Do not connect either the wall switch, thermostat or gas valve directly to 
110 volt electricity.

OPTIONAL WALL SWITCH INSTALLATION

Conversion Kits

The mobile home appliance is fi eld convertible between Natural Gas (NG) and Propane (LP).

To convert from one gas to another consult your Napoleon® dealer/distributor. 

MANUAL SHUT-OFF VALVE

P

I

PILOT

N

O

L

O

T

H I

L O

FF

O

WIRE SIZE

LENGTH

14 Gauge

100 Feet

16 Gauge

60 Feet

18 Gauge

40 Feet

P

I

P ILOT

3

1

N

O

L

O

T

H I

L O

FF

O

GD36 RESTRICTING VERTICAL VENTS 

Vertical terminations running longer than 15 feet may display a very active fl ame.  If this appearance is not desirable, the 
vent exit must be restricted using restrictor plate kit, RP-KT. 

This reduces the velocity of the exhaust gasses, slowing down the fl ame pattern and creating a more traditional appearance.  
Specifi c instructions are included with the kit.

FIGURE 43

NorthlineExpress.com

http://www.northlineexpress.com

Toll-Free 1-866-667-8454

Summary of Contents for GD36NTR

Page 1: ...other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighb...

Page 2: ...ace is out the glass and or screen will remain hot for an extended period of time Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfac...

Page 3: ...3 W415 0210 R 02 27 08 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Page 4: ...le or other combustible material other than wood flooring the fireplace shall be installed on a metal or wood panel extending the full width and depth If the optional fan or blower is installed the ju...

Page 5: ...r the first 10 hours of operation with a recommended gas fireplace glass cleaner Thereafter clean as required DO NOT CLEAN GLASS WHEN HOT If the glass is not kept clean permanent discolouration and or...

Page 6: ...RISE ON HORIZONTAL VENTING BGD36 REQUIRED RISE ON HORIZONTAL VENTING REAR VENT RIGID VENTING 1 FT REAR VENT RIGID VENTING 0 FT FLEXIBLE VENTING 1 FT FLEXIBLE VENTING 0 FT TOP VENT RIGID VENTING 0 FT...

Page 7: ...4a 20 MAXIMUM FIGURE 4b BGD36 ONLY WITH RIGID ONLY 6 RISE MINIMUM FIGURE 2c FIGURE 2d GD36 See chart on Page 6 20 MAXIMUM 241 4 MINIMUM PLUS RISE 24 MAXIMUM 24 MINIMUM 57 MINIMUM PLUS RISE 33 BGD36 F...

Page 8: ...8 W415 0210 R 02 27 08 FIGURE 5 MINIMUM AIR TERMINAL LOCATION CLEARANCES NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Page 9: ...to or greater t h a n t h e horizontal run Horizontal run verti cal rise to m a x i m u m of 40 feet Vertical rise is equal to or greater t h a n t h e horizontal run Horizontal run verti cal rise to...

Page 10: ...than less than equal to or less than HT total of both horizontal vent lengths HR and offsets HO in feet HR combined horizontal vent lengths in feet HO offset factor 03 total degrees of offset 90 in f...

Page 11: ...1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 four 90 elbows 90 03 360 90 8 1 ft HT HR HO 5 5 8 1 13 6 ft HT VT 13 6 5 5 19 1 ft Formula 1 HT 4 2 VT 4 2 VT 4 2 x 5 5 23 1 ft 13 6 23 1 Formula 2 HT VT 24 75 feet 1...

Page 12: ...0 03 90 90 90 90 90 8 1 ft HT HR HO 6 5 8 1 14 6 ft HT VT 14 6 15 29 6 ft Formula 1 HT VT 14 6 15 Formula 2 HT VT 40 feet 29 6 40 Since both formulas are met this vent configuration is acceptable FIGU...

Page 13: ...4 75 Since both formulas are met this vent configuration is acceptable FIGURE 14 For vent configurations requiring more than two 90 elbows the following formulas apply Formula 1 HT 3 5VT Formula 2 HT...

Page 14: ...this vent configuration is acceptable Simple venting configurations FIGURE 15 For vent configurations requiring more than zero 90 elbow top exit or one 90 elbow rear exit the following formulas apply...

Page 15: ...t this vent configuration is unacceptable and a new fireplace location or vent configuration will need to be established to satisfy both formulas Example 8 V1 1 5 ft V2 5 ft VT V1 V2 1 5 5 6 5 ft H1 1...

Page 16: ...through the heat shield and out through the retaining ring Secure the assembly to the rear and top of the unit using 4 8 x Hex Head Wildrill screws supplied Do not overtighten The gasket needs only to...

Page 17: ...may need to be repositioned to ensure a rigid assembly is maintained Figure 25 2 Apply a bead of caulking not supplied to the inside surface of the firestop flange and secure the assembly to the wall...

Page 18: ...nt any materials such as insulation from filling up the 1 air space around the pipe VERTICAL INSTALLATION FIGURE 29 FIGURE 28 FIRESTOP UNDERSIDE OF JOIST 9 1 2 9 1 2 SHIELD FIGURE 30 VENT PIPE COLLAR...

Page 19: ...IBLE VENT PIPE SCREWS 10x2 VENT PIPE 2 OVERLAP 7 FLEXIBLE 4 FLEXIBLE VENT PIPE CAULKING ATTENTIO N C HAUD CAUTIO N HOT HIGH TEMPERATURE SEALANT FIGURE 32 1 Stretch the 4 flexible vent pipe to the requ...

Page 20: ...ing material Figure 36 6 Aligning the seams of the terminal and air terminal connector place the terminal over the air terminal connector making sure the vent pipe goes into the hole in the terminal S...

Page 21: ...this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support 3 Apply high temperature sealant W573 0...

Page 22: ...tes or the Mobile Home Standard CAN CSA Z240 MH Series in Canada This appliance is only for use with the type s of gas indicated on the rating plate A conversion kit is supplied with the mobile home a...

Page 23: ...material brick stone or ceramic tile may protrude in these areas FIGURE 45 Bend and secure the top stand off s as illustrated A B C STAND OFF ASSEMBLY MINIMUM FRAMING DIMENSIONS FIGURE 44 a d Combust...

Page 24: ...ace areas of the fireplace Non combustible material brick stone or ceramic tile may protrude in these areas MINIMUM FRAMING DIMENSIONS FIGURE 46 a d Combustion protrusions such as mantels and shelves...

Page 25: ...ires a minimum enclosure height of 483 8 Fortemperaturerequirements theenclosurespace around and above the fireplace must be left unobstructed The fireplace requires a minimum enclosure height of 63 F...

Page 26: ...on of the nailing tab you must first determine the thickness of your finishing material i e drywall This will determine the dimension from the front edge of the corner post to the nailing tab Once the...

Page 27: ...t LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left and right corners of the unit To remove the louvres pull the back tabs of the clips forward while pushing the louvre as...

Page 28: ...of the bag should not be used Sprinkle vermiculite around the charcoal embers Note Both charcoal embers and vermiculite are not to be placed on the burner Tear the embers into pieces and place along...

Page 29: ...touch the fireplace base or the firebox FIGURE 59 FIGURE 60 Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the securing stud at the bottom...

Page 30: ...on box at the bottom left of the unit using the lock washer and wing nut Ensure that the thermodisc touches the firebox wall When installed ensure that any excess wire is contained pre venting it from...

Page 31: ...knob while lighting the pilot with the push button igniter Keep knob depressed for one minute then release If pilot does not continue to burn repeat steps 3 through 5 7 With pilot lit depress and tur...

Page 32: ...THERMOCOUPLE THERMOPILE Adjust the pilot screw to provide properly sized flame Turn in a clockwise direction to reduce the gas flow FIGURE 70 VENTURI ORIFICE AIR SHUTTER OPENING FIGURE 72 FIGURE 69 P...

Page 33: ...PLATE KIT 65 VS47KT VENT SLEEVE 66 W573 0002 HIGH TEMPERATURE SEALANT 67 W573 0007 HIGH TEMPERATURE SEALANT PART NO DESCRIPTION 1 W225 0058 BLACK DOOR FRAME 2 W357 0001 PIEZO IGNITER 3 W680 0004 THERM...

Page 34: ...0 1774 FIRESTOP SPACER BGD36 ACCESSORIES 76 W175 0159 CONVERSION KIT NG TO LP 77 W175 0164 CONVERSION KIT LP TO NG GD36 COMPONENTS 68 W455 0017 42 NATURAL GAS ORIFICE 68 W455 0003 54 PROPANE GAS ORIFI...

Page 35: ...ot burner check that the manual valve is turned on check the pilot orifice for blockage replace the valve call the gas distributor Pilot goes out when the gas knob is re leased The gas valve has an in...

Page 36: ...nt or other obstructions Pilot goes out while standing Main burner is in OFF position Gas piping is undersized turn on all gas appliances and see if pilot flame flutters diminishes or extinguishes esp...