EN
W415-3006 / A / 05.27.21
11
3.0 location
It is important when selecting a location for your appliance to ensure clearances to adjacent combustibles are
met. This appliance is intended for installation on an outdoor patio or in your yard. It is highly recommended that
this appliance be installed in a sheltered area (following the guidelines outlined below). Direct wind will cause an
erratic flame and possible pilot or main burner outage. An erratic flame could also lead to excessive carboning
(black soot), which is not a safety issue but is visually undesirable.
Any enclosure (shelter) in which the appliance is used must comply with one of the following:
With walls on all sides, but at least one permanent opening at ground level and no overhead cover
(Fig. 1)
.
Within a partial enclosure which includes an overhead cover and no more than two sidewalls. These sidewalls may
be parallel, as in a breezeway, or at right angles to each other
(Fig. 2)
.
Within a partial enclosure which includes an overhead cover and three widewalls, as long as 30 percent or more
of the horizontal periphery of the enclosure is permanently open
(Fig.3)
.
When choosing a location for your appliance, care must be taken to avoid areas where excessive moisture or
running water may be a problem.
note:
Fig. 1
Fig. 2