background image

EN

W415-1789 / C / 01.29.19

3

  

 

1.0  installation planning

!

WARNING

•  Dynamic Heat Control™ Plus (DHC™ Plus) CANNOT 

be installed without Dynamic Heat Control™.

•  DHC™ Plus

 is ONLY compatible with Dynamic Heat Control™ 

Installation Option #2

 (front opening) or 

Installation Option #3

 (rear opening).

•  DHC™ Plus MUST

 be installed with an air outlet opening or it will become a potential fire hazard.

•  Installation must conform to local codes or, in the absence of local codes, the National Gas and Propane 

Installation Code CSA B149.1 in Canada, or the National Fuel Gas Code ANSI Z223.1 / NFPA 54 in the United 

States.

•  An appliance may use only one 

DHC™ Plus

 blower kit.

•  We recommend installing

 DHC™ Plus

 during installation of the appliance 

BEFORE 

appliance venting and gas 

are installed.

•  Installation 

MUST 

be performed by a qualified installer who has completed the Dynamic Heat Control™ System 

Certification course via Napoleon’s online education portal NEducation.

•  Ensure the appliance is completely cool before starting installation.

•  To avoid danger of suffocation, keep the packaging bag away from babies and children. Do not use in cribs, 

beds, carriages, or play pens. This bag is not a toy. Knot before throwing away.

Dynamic Heat Control™ Plus (DHC™ Plus) 

is a system for managing the heat produced by the appliance at 

and around the appliance. The purpose of

 DHC™ Plus 

is to move heat away from the appliance and to primarily 

distribute some or all of it to the exterior. Where duct lengths are greater than 5 feet or when passing through 

uninsulated spaces such as an attic, it is recommended that the duct be insulated.

Whilst it is practically possible to use DHC™ Plus to move heat to another location within the home, 

please consider the following points carefully during the planning phase:

•  The sound of the 

DHC™ Plus

 blower is similar to a bathroom fan (see “sound considerations” section). 

•  The 

DHC™ Plus

 system should not be used in small enclosed rooms with low ceilings, such as a small 

bathroom, as the room will be quickly pressurized and the heat transfer from the fireplace will be reduced / 

eliminated. 

•  The 

DHC™ Plus

 moves almost all the useable 

heat. If the room is small in volume, it can quickly 

become very warm. You may move unwanted 

heat from one room to another, which may not 

satisfy the customer. Therefore, carefully consider 

the amount of heat and the size of the room 

where it is being transferred to before beginning 

installation.

•  Where the

 DHC™ Plus

 system is used to transfer heat to another room, it is recommended to install a local 

on/off switch so that the heat transfer can be disabled from the remote location if desired. The 

DHC™ Plus 

system does not include a remote room thermostat.

1.1 introduction

1.2 

installation options

There are three installation options available for

 DHC™ Plus

, each with its own advantages:

Exterior Installation

DHC™ Plus

 is installed on the exterior wall of the appliance enclosure. It does not require venting, ducting, or a 

bulkhead, and is therefore the simplest installation option. However, careful consideration should be made for the 

sound of the

 DHC™ Plus

 blower. See “sound considerations” and “exterior installation” sections for details.

Remote Exterior Installation

DHC™ Plus

 is installed remotely from the appliance enclosure. Though it requires venting and a bulkhead, the 

increased distance from the blower ensures sounds from air flow will be significantly less apparent. See “sound 

considerations” and “remote exterior installation” sections for details.

Remote Inline Installation

DHC™ Plus

 is installed inline anywhere between the appliance enclosure and the hot air exhaust assembly. 

Similarly to remote exterior installations, this installation requires venting and a bulkhead, with the addition of 

ducting. This installation offers the most opportunity for unique configurations, including through multiples rooms 

or floor levels. See “remote inline installation” section for details.

Summary of Contents for DHCP-BK

Page 1: ...tion and service must be performed by a qualified installer service agency or the supplier Thisappliancemaybeinstalledinanaftermarket permanently located manufactured home USA only or mobile home wher...

Page 2: ...serves the right to change or modify any information within this manual at any time without notice Changes other than editorial are denoted by a vertical line in the margin note WARNING This product c...

Page 3: ...section The DHC Plus system should not be used in small enclosed rooms with low ceilings such as a small bathroom as the room will be quickly pressurized and the heat transfer from the fireplace will...

Page 4: ...rise of up to 2 boxes Please read carefully and ensure to order correct ap plication kits for your unique installation note 7 2 3 4 5 6 1 8 9 14 Thread RH 0 141 Hex 0 348 9 1 3 1 DHCP BK Though not su...

Page 5: ...ducting that is not supplied Exterior Installation N A Remote Exterior Installation 6 steel rigid venting between appliance enclosure and DHC Plus blower kit Remote Inline Installation 6 steel ductin...

Page 6: ...lus system No other items are allowed in this area See your appliance manual for more information about clearance to combusible materials No combustible materi als allowed in the hatched areas or the...

Page 7: ...1 1 7 1 DHCP BK DHCP EK 1 7 2 DHCP BK DHCP HK top view 14 1 4 362mm 6 152mm 3 3 16 81mm 1 2 13mm 14 3 16 360mm 13 3 16 335mm 4 102mm 6 152mm 3 1 2 90mm 3 7 8 98mm 6 3 16 157mm 6 152mm 9 5 16 236mm 1 1...

Page 8: ...on mechanical air supply inlet to the building or a combustion air inlet to any other appliance J 6 1 8m 3 0 9m Clearance to a mechanical air supply inlet K 7 2 1m 7 2 1m Clearance above a paved sidew...

Page 9: ...en the blower is not running for the system to function correctly FOR EXTERIOR AND REMOTE EXTERIOR INSTALLATIONS ONLY 9 14 Thread RH Hex x 4 x 3 3 Install the air damper assembly onto the collar and s...

Page 10: ...ce Vent Terminal if applicable Required WARNING Minimum clearance to combustibles must be maintained or a serious fire hazard could result DO NOT cover or place any items in the Dynamic Heat Control a...

Page 11: ...otrusion from the finished exterior wall and then fasten the wall flashing using 4 screws supplied Fig 2 See mounting options section for details Fig 1 Fig 2 x 4 17 1 4 44cm 14 1 2 36 8cm Interior Ext...

Page 12: ...he appropriate fasteners not supplied Fig 3 4 Apply silicone to the joint after installation and caulk or seal the wall flashing appropriately for the finish mate rial Fig 4 5 We recommend installing...

Page 13: ...EK 2 Air damper assembly installed and checked 3 Rough opening framed into exterior wall 4 Wall flashing installed and sealed appropriately for finish material 5 DHCP EK attached to exterior wall 6 I...

Page 14: ...to 60 18 2m away 5 1 remote exterior installation overview WARNING DHCP BK DHCP EK Required Venting 6 rigid steel not supplied Minimum clearance to combustibles must be maintained or a serious fire ha...

Page 15: ...2mm Fig 1 Left Side Profile View 2 Using appropriate fasteners not supplied secure the 6 152mm collar plate assembly over the hole inside the bulkhead Fig 2 3 Install 6 rigid steel venting not supplie...

Page 16: ...flashing installed and sealed appropriately for finish material 5 DHCP EK attached to exterior wall 6 Inline cover assembly installed see electrical informa tion section 7 Decorative cover installed a...

Page 17: ...ill vary depending on the appliance size See minimum venting requirements section of your appliance manual for details In this mounting option the wall flashing and exterior housing assembly are flush...

Page 18: ...m 6 152mm Hole Installed Collar Plate Assembly Exterior Interior Air Damper Assembly 6 Rigid Steel Venting Appliance LVX38 Illustrated Installed 6 Collar Plate Assembly Exterior Housing Assembly Inter...

Page 19: ...l Venting Appliance LVX38 Illustrated Installed 6 Collar Plate Assembly Exterior Housing Assembly Interior Exterior Due to a variety of potential finish materials brackets to mount DHC Plus need to be...

Page 20: ...h the 6 152mm collar connector assembly to the blower housing assembly using self drilling screws sup plied Fig 2 3 Attach the mounting brackets to the blower housing assembly using screws supplied Fi...

Page 21: ...lation must comply with all electrical and local codes DHCP BK DHCP HK Required WARNING note MUST have access panel for service or maintenance of blower Minimum clearance to combustibles must be maint...

Page 22: ...mbly on the exterior wall and frame a 14 1 2 36 8cm wide by 11 3 8 28 9cm high opening Fig 1 2 Fasten the wall flashing onto the hot air exhaust assembly using 4 screws supplied Fig 2 x 4 11 3 8 28 9c...

Page 23: ...xhaust assembly to the exterior wall by securing the wall flashing with appropriate fasten ers not supplied Fig 3 4 Apply silicone to the joint after installation and caulk or seal the flashing approp...

Page 24: ...from the blower housing assembly outlet to the hot air ex haust assembly Fig 4 note Ensure to maintain 1 25mm clearance to combustibles Fig 3 Fig 4 Inside View of Bulkhead Some Framing and Finishing...

Page 25: ...ng completed see electrical information section 13 On off switch adjusted to fully on position DHCP HK Collar Connector Assembly Mounting Bracket x2 Wall Flashing Air Damper Assembly Exterior Interior...

Page 26: ...side Fig 4 next page Remove the decorative cover and set it aside Blower Lamp REMOVE WIRES TWO BLOWER WIRES AS SHOWN BLOWER LAMP TERMINAL BLOCK TOP VIEW LAMP COMFORT FAN BLOWER BLOWER LAMP TERMINAL BL...

Page 27: ...stud whenever possible Armoured cable should also be installed as close to the outside of the enclosure and as far away from the appliance as possible 13 Connect the opposite end of the on off switch...

Page 28: ...hot and neutral wires from the Proflame 2 are properly connected to the wall switch box 3 Connect the hot wire from the on off switch to the wall switch 4 Connect the neutral wires to each other from...

Page 29: ...upplied at the location 3 Ensure the wires for the wall are properly wired to the switch box and are ready 4 Connect the hot wire from the on off switch to the wall switch 5 Connect the neutral wires...

Page 30: ...noise depending on the location of the DHC Plus blower kit For optimal performance the on off switch in the blower housing must ALWAYS be set to the maximum speed setting 10 2 using remote control The...

Page 31: ...replacement parts a photocopy of the original invoice will be required to honour the claim When ordering replacement parts always give the following information Model Serial Number of appliance Instal...

Page 32: ...ocked 1 W010 4481 SER Air damper assembly 2 3 4 Ref No Part Number Description 7 Stocked 6 2 1 2 2 2 3 2 4 2 5 2 7 2 6 W062 0078 SER DHC Plus blower W660 0113 On off switch W010 4544 Inline cover asse...

Page 33: ...89 C 01 29 19 33 replacement parts 11 2 DHCP EK overview Items may not appear exactly as illustrated Ref No Part Number Description Stocked 2 2 1 2 2 W263 0214 SER Wall flashing W200 0764 SER Decorati...

Page 34: ...C 01 29 19 EN 34 replacement parts 11 3 DHCP HK overview Items may not appear exactly as illustrated Ref No Part Number Description Stocked 2 2 1 2 2 W263 0213 SER Wall flashing W305 0007 SER Louvere...

Page 35: ...EN W415 1789 C 01 29 19 35 12 0 notes...

Page 36: ...COMFORT PRODUCTS 7200 Route Transcanadienne Montr al Qu bec H4T 1A3 24 Napoleon Road Barrie Ontario Canada L4M 0G8 214 Bayview Drive Barrie Ontario Canada L4N 4Y8 103 Miller Drive Crittenden Kentucky...

Page 37: ...appareil ne peut tre converti d autres gaz sauf si une trousse de conversion est utilis e RISQUE D INCENDIE OU D EXPLOSION Incapacit suivre ces avertissements exactement peuvent entra ner de grave ble...

Page 38: ...nue dans ce manuel tout moment sans pr avis Les modifications autres que les ditoriaux sont d signes par une ligne verticale dans la marge note AVERTISSEMENT Ce produit peut vous exposer des substance...

Page 39: ...t utilis pour transf rer de la chaleur dans une autre pi ce il est recommand d installer un interrupteur marche arr t dans cette pi ce afin que le transfert de chaleur puisse tre d sactiv distance si...

Page 40: ...ext rieur Dans cette option l installation du syst me DHCMD Plus se fait sur le mur ext rieur de l enceinte de l appareil Il ne n cessite pas d vacuation ni de conduit ni de cloison et est donc l opt...

Page 41: ...1 10 Thread RH 29 64 1 8 1 1 2 Quadrex Drive 9 14 Thread RH 0 141 Hex 0 348 R f Description R f Description 1 Ensemble quincaillerie 3 Ensemble d vacuation d air chaud 2 Solin mural R f Description R...

Page 42: ...rigide en acier de 6 po entre l ensemble de ventilateur DHCMD Plus et l ensemble d vacuation d air chaud 1 5 ventilation conduits D terminez l emplacement de l ensemble du ventilateur avec soin car le...

Page 43: ...e l ment n est autoris dans ce domaine Consultez le manuel de votre appareil pour plus de d tails propos des d gagements aux mat riaux combus tibles Aucun mat riau combustible n est autoris dans la zo...

Page 44: ...13mm 14 3 16 360mm 13 3 16 335mm 4 102mm 6 152mm 3 1 2 90mm 3 7 8 98mm 6 3 16 157mm 6 152mm 9 5 16 236mm 1 13 16 46mm 8 199mm TITLE ASSEMBLY BLOWER KIT MODEL DRAWN BY U FINISH U REVISION CHECKED BY S...

Page 45: ...ion de tout autre appareil J 6 1 8m 3 0 9m D gagement d une prise d air m canique K 7 2 1m 7 2 1m D gagement au dessus d un trottoir ou d une entr e pav e situ es sur une propri t publique L 12 30 5cm...

Page 46: ...is fournies Fig 2 Fig 2 Fig 3 note Le registre d air doit se fermer lorsque le ventilateur ne fonctionne pas pour que le syst me fonctionne correctement 9 14 Thread RH Hex x 4 x 3 3 Installez le regis...

Page 47: ...e les d gagements minimaux aux mat riaux combustibles doivent tre maintenus NE couvrez PAS la sortie d air du syst me Dynamic Heat ControlMD et ne d posez pas d objets sur celle ci Le non respect de c...

Page 48: ...nimales en mati re d ossature 1 D terminez l emplacement d sir du bo tier ext rieur sur le mur ext rieur puis d coupez et charpentez une ouverture de 14 1 2 po 36 8cm de large et de 17 1 4 po 44cm de...

Page 49: ...ellez le solin mural de mani re correcte pour le mat riau de finition Fig 4 5 Nous vous recommandons d attendre d avoir install tout le c blage lectrique pour poser l assemblage du panneau d acc s en...

Page 50: ...EK 2 Registre d air install et v rifi 3 Ouverture brute charpent e dans le mur ext rieur 4 Solin mural install et scell de mani re correcte pour le mat riau de finition 5 Ensemble DHCP EK fix au mur e...

Page 51: ...AS la sortie d air du syst me Dynamic Heat ControlMD et ne d posez pas d objets sur celle ci Le non respect de ces instructions pourrait augmenter le risque d incendie Le syst me DHCMD Plus NE PEUT PA...

Page 52: ...hes appropri es non fournies Fig 2 3 Installez un composant d vacuation rigide en acier de 6 po non fourni de l enceinte de l appareil jusqu au bo tier du ventilateur Fig 3 Fig 2 Fig 3 GLASS GUARD LVX...

Page 53: ...fix 10 Composant d vacuation rigide en acier de 6 po non fourni install 11 C blage compl t consultez la section information lectrique 12 Interrupteur on off ajust on compl tement DHCP BK DHCP EK Regi...

Page 54: ...tez la section exigences d vacuation minimales du manuel de votre appareil pour obtenir de plus amples d tails Pour cette option de fixation le solin mural et le bo tier ext rieur sont install s galit...

Page 55: ...ur Registre d Air Composant d vacuation Rigide en Acier de 6 po non fourni Appareil LVX38 Illustr Plaque de Collet 6 po Install Bo tier Ext rieur Int rieur Ext rieur Aucun autre type de mat riaux ne p...

Page 56: ...r Ext rieur En raison de la vari t des mat riaux de finition possibles les supports de montage du syst me DHCMD Plus doivent tre fabriqu es sur place avec des mat riaux appropri es et fix es l aide vi...

Page 57: ...collet de 6 po 152mm sur le bo tier du ventilateur l aide de vis autoperceuses fournies Fig 2 3 Fixez les supports sur le bo tier du ventilateur l aide de vis autoperceuses fournies Fig 3 POUR UNE INS...

Page 58: ...entretien du ventilateur Conduit en acier de 6 po non fourni Afin d viter un risque d incendie grave les d gagements minimaux aux mat riaux combustibles doivent tre maintenus NE couvrez PAS la sortie...

Page 59: ...28 9cm 14 1 2 po 36 8cm min Int rieur Ext rieur note Pour une performance optimale nous recommandons d installer le syst me DHCMD Plus dans la section de 12 po 30 5cm qui se trouve dans le haut de l e...

Page 60: ...taches ap propri es non fournies Fig 3 4 Appliquez du silicone sur le joint apr s l installation et calfeutrez ou scellez le solin mural de mani re correcte pour le mat riau de finition Fig 4 5 D term...

Page 61: ...une cloison particuli rement celle traversant plusieurs pi ces ou espaces veillez toujours respecter toutes les exigences et les codes du b timent locaux note Assurez vous de d couper le trou de 6 po...

Page 62: ...mation lectrique 13 Interrupteur on off ajust on compl tement DHCP HK Connecteur de Collet Support de Montage x2 Solin Mural Registre d Air Ext rieur Int rieur Plaque de Collet de 6 po Composant d vac...

Page 63: ...BLOC DE BRANCHEMENT SOUFFLERIE AMPOULE VUE DE DESSUS LAMP COMFORT FAN BLOWER BLOC DE BRANCHEMENT SOUFFLERIE AMPOULE LAMP COMFORT FAN APPLIANCE CONTROLLER BLOWER AVERTISSEMENT Cet appareil doit tre rac...

Page 64: ...l interrupteur on off 10 Thread RH 29 64 1 8 1 1 2 Quadrex Drive x2 note Assurez vous d utiliser un c ble arm les connecteurs et un soulagement de traction appropri s pour l installation non fournis L...

Page 65: ...res du Proflame 2 sonts connect s correctement la bo tier de l interrupteur de mur 3 Connectez le fil charg de l interrupteur on off l interrupteur de mur 4 Connectez les fils neutres les uns aux autr...

Page 66: ...ilateur la source d alimentation neutre N 6 Connectez tous les terres de la source d alimentation au ventilateur Prise de Terre L gende Conexion sur le Terrain L N Interrupteur de Mur G Source d Alime...

Page 67: ...n de l emplacement du bo tier du ventilateur du syst me DHCMD Plus Pour une performance optimale l interrupteur on off dans le bo tier du ventilateur doit TOUJOURS tre regl au r glage de la vitesse ma...

Page 68: ...ce sous garantie une photocopie de la facture originale sera requise afin de pouvoir honorer la demande Lorsque vous commandez des pi ces donnez toujours l information suivante Mod le et num ro de s r...

Page 69: ...10 4481 SER Registre d air 2 3 4 R f No de Pi ce Description 7 En Stock 6 2 1 2 2 2 3 2 4 2 5 2 7 2 6 W062 0078 SER Ventilateur du syst me DHC Plus W660 0113 Interrupteur on off W010 4544 L assemblage...

Page 70: ...19 70 FR pi ces de rechange 11 2 vue d ensemble de DHCP EK Ces articles peuvent diff rer de celles illustr es R f No de Pi ce Description En Stock 2 2 1 2 2 W263 0214 SER Solin mural W200 0764 SER Cou...

Page 71: ...19 71 pi ces de rechange FR 11 3 vue d ensemble de DHCP HK Ces articles peuvent diff rer de celles illustr es R f No de Pi ce Description En Stock 2 2 1 2 2 W263 0213 SER Solin mural W305 0007 SER Gr...

Page 72: ...EPTION DE PRODUITS DE CONFORT 7200 Route Transcanadienne Montr al Qu bec H4T 1A3 24 Napoleon Road Barrie Ontario Canada L4M 0G8 214 Bayview Drive Barrie Ontario Canada L4N 4Y8 103 Miller Drive Critten...

Reviews: