background image

NAPCO Security Systems  

LIBRA LIB-P432EX Series Programming Instructions 

Page 45

 

ZONE OPTIONS - ZONES 1 TO 16 (ADDRESS 0900-1016) 

 

 

ZONE OPTIONS 

ZONES 13-16    

LEFT DATA VALUES 

(CIRCLE 

 

 

ADDRESS 

ZONES 9-12            

RIGHT DATA VALUES 

(CIRCLE 

 

ZONES 5-8  

 LEFT DATA VALUES 

(CIRCLE 

 

 

ADDRESS  

ZONES 1-4  

 RIGHT DATA VALUES 

(CIRCLE 

 

 

 

ZN16  ZN15  ZN14  ZN13  L  ADDR  R  ZN12  ZN11  ZN10  ZN9  ZN8  ZN7  ZN6  ZN5 

L  ADDR  R  ZN4  ZN3  ZN2  ZN1 

         

§ 

50ms Loop Response

 

 

0964 

 

 

0900 

 

 

Priority 

 

0965 

 

 

0901 

 

 

Priority with Bypass 

 

0966 

 

 

0902 

 

 

Auto-Bypass 

 

0967 

 

 

0903 

 

 

Selective Bypass 

 

0968 

 

 

0904 

 

 

Keyswitch Arming 

 

0969 

 

 

0905 

 

 

Auto-Bypass Re-entry 

 

0970 

 

 

0906 

 

 

Pre-Alarm Warning 

 

0971 

 

 

0907 

 

 

Never Arm 

 

0972 

 

 

0908 

 

 

24-Hour Zone 

 

0973 

 

 

0909 

 

 

Alarm Output 

 

0974 

 

 

0910 

 

 

 

Pulsed Alarm Output 

 

0975 

 

 

0911 

 

 

PGM1 Output 

 

0976 

 

 

0912 

 

 

PGM2 Output 

 

0977 

 

 

0913 

 

 

 

Entry/Exit 1 

 

0978 

 

 

0914 

 

 

Entry/Exit 2 

 

0979 

 

 

0915 

 

 

 

Exit/Entry Follower 

 

0980 

 

 

0916 

 

 

Auto Reset 

 

0981 

 

 

0917 

 

 

Swinger Shutdown 

 

0982 

 

 

0918 

 

 

 

Chime 

 

0983 

 

 

0919 

 

 

Abort Delay 

 

0984 

 

 

0920 

 

 

Power-up Delay 

 

0985 

 

 

0921 

 

 

Day Zone Open 

 

0986 

 

 

0922 

 

 

Day Zone Short 

 

0987 

 

 

0923 

 

 

Alarm on Day Zone 

 

0988 

 

 

0924 

 

 

 

Alarm Telco 1 

 

0989 

 

 

0925 

 

 

Alarm Restore 1 

 

0990 

 

 

0926 

 

 

Trouble Telco 1 

 

0991 

 

 

0927 

 

 

Trouble Restore 1 

 

0992 

 

 

0928 

 

 

Alarm Telco 3 

 

0993 

 

 

0929 

 

 

Alarm Restore 3 

 

0994 

 

 

0930 

 

 

Trouble Telco 3 

 

0995 

 

 

0931 

 

 

Trouble Restore 3 

 

0996 

 

 

0932 

 

 

No EOL Resistor 

 

0997 

 

 

0933 

 

 

Trouble on Open 

 

0998 

 

 

0934 

 

 

Trouble on Short 

 

0999 

 

 

0935 

 

 

 

Zone Area 1 

 

1000 

 

 

0936 

 

 

Zone Area 2 

 

1001 

 

 

0937 

 

 

Interior (Stay) Bypass 

 

1004 

 

 

0940 

 

 

Keypad Sounder on Alarm 

 

1005 

 

 

0941 

 

 

 

2-Wire Smoke Detectors

 

(•)  1006  (•) 

8 4 

 

0942  (•) 

 

 

Fire 

 

1007 

 

 

0943 

 

 

Fire Alarm Verification

 

 

1008 

 

 

0944 

 

 

RESERVED 

(•)  1009  (•) 

(•)  0945  (•) 

 

Zone ANDing Group 1 

 

1010 

 

 

0946 

 

 

Zone ANDing Group 2 

 

1011 

 

 

0947 

 

 

Zone ANDing Group 3 

 

1012 

 

 

0948 

 

 

Zone ANDing Group 4 

 

1013 

 

 

0949 

 

 

Sensor Watch 

 

1014 

 

 

0950 

 

 

RESERVED 

 

1015 

 

 

0951 

 

 

Chime 2 

 

1016 

 

 

0952 

 

 

 
 

 
 

 
 

 
 

 
 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 

§

  50ms Loop Response only available for zones 1-4.  If Zone Doubling is enabled, Zones 9-12 will follow the loop response programming for Zones 1-4.   

 

 When the Easy Program Menu is used, these features are enabled by default. 

  

Enabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu). 

  

Disabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu).  Disable Auto-Reset on non-fire zones for SIA CP-01 installations. 

NOTE:  

(Address Location 0942 can only be programmed as "blank (•) blank (•)", "4 blank (•)", "8 blank (•)" or "C blank (•)".  

 

 

Zone Area 3 

 

1002 

 

 

0938 

 

 

Zone Area 4 

 

1003 

 

 

0939 

 

1. 

Select

 the desired zone option. 

 

ZONE OPTIONS 

§ 

50ms Loop Response 

 

Priority 

 

Priority with Bypass 

 

Auto-Bypass 

 

Selective Bypass 

3. 

Search table

 below for data entry. 

4. 

Enter data

 in address locations (left and right 

digits).  Press [Enter] or [ON/OFF] to save. 

ADDR 

blank (•)  0490 

ADDRESS LOCATION  

NOTE:

  Dark shaded boxes = option not available.   

See Direct Address Programming Example page 22. 

4

8

2 1

DIGIT VALUE DATA ENTRY

Blank (

.

)

4

8

2 1

1

4

8

2 1

2

8

1

2

4

3

4

8

2 1

4
5

4

8

2 1

4

8

2 1

6

4

8

2 1

7

4 2 1

DIGIT VALUE DATA ENTRY

8

4 2 1

9

4 2 1

0

1

2

4

B

4 2 1

C
D

4 2 1
4 2 1

E

4 2 1

F

8
8
8
8
8
8
8
8

Step 1 

Step 4 

Step 4 

Step 4 

Step 4 

Step 2 

Step 2 

Step 2 

Step 2 

See steps listed at 

bottom of page 

2. 

Enable

 desired options for each zone 

by drawing a circle   around its 
corresponding binary data value.  

NOTE:

 

No circle = feature disabled. 

Summary of Contents for LIBRA LIB-P432EX

Page 1: ...u Driven Dealer Program Mode Press 456789 w Press NO X or q until TURNON PROG Y N appears on the keypad Press YES r or p to enter Dealer Program Mode See page 5 Quick Start for GEM DXK3 1 Refer to the...

Page 2: ...be used in this manual as well The Instant z button and the AWAY q button operate identically in Program Mode for both key pads These buttons are also used to answer NO or PRIOR to questions that app...

Page 3: ...ber of Keypads 16 Central Station Receiver 1 Tel Number 16 Central Station Receiver 1 Account Number 16 Central Station Receiver 1 Format 16 Enter User Codes 16 RF Transmitter Points 17 Key Fob Transm...

Page 4: ...ad Programming The Direct Address Program Mode is an extension of the Dealer Program Mode wherein data is entered at the keypad by specific location This mode is accessed from the Easy Menu Driven Pro...

Page 5: ...on Alarm Zones Auto Bypass re entry Zones Enable no EOLR Zones Enable Telco Line Fault Test Enable Burg Output Chirp on Keyfob Enable CP 01 Number of Keypads in Area 1 Central Station Receiver 1 Tel...

Page 6: ...tallation Instructions If Panel Zone doubling is not desired press PRIOR X or q Fire Zones in Area 1 Appears for New Panel Only Enter the zone number of any zones which are to be used as Fire Zones bo...

Page 7: ...a distinct pulsating tone when zone is faulted Exit Entry2 Zones in Area 1 New Program Only Enter the zone numbers of zones to be used as Exit Entry 2 zones Valid entries are from 01 to 32 Directly e...

Page 8: ...designed to reduce the incidence of false alarms See WI1691 Installer Pro gramming Quick Reference Chart SIA False Alarm Reduction and LIB P432EX Factory Default Description for more information NOTE...

Page 9: ...w once to set the cursor to the User Code Use the number buttons 1 through 9 to enter a code from 3 to 6 digits Enter up to 6 digits 4 digits is recommended in the first six boxes from left to right...

Page 10: ...has been successfully enrolled Multi point transmitters can be mapped to successive zones simultaneously see example Example A 2 point transmitter has the RF ID number 287613 1 Map point 1 to Zone 6...

Page 11: ...to a Central Station or a pager and or annunciating on a keypad the key fob zone number with description location To assign a key fob to a zone program the keyfob as you would a transmitter entering...

Page 12: ...is not allowed NOTE Enter Easy Menu Driven Program Mode to program system again Cold Start Erases Entire Program This erases the entire program including Dealer Program by erasing Program Data Zone D...

Page 13: ...se number buttons 1 through 9 NOTE Press the 0 button for a zero Press u to save and then repeat for any additional zone s Press NEXT r or p to proceed NOTE Exit Entry Zones will have an entry delay o...

Page 14: ...one is faulted Exit Entry2 Zones in Area 1 New Program Only Enter the zone numbers of zones to be used as Exit Entry zones Valid entries are from 01 to 32 Directly enter each zone number including lea...

Page 15: ...d Enable No EOLR Zones New Program Only Press NEXT r or p to program all zones except 24 Hr fire zones for No End Of Line Resistor Press the PRIOR NO button to continue Enable Telco Line Fault Test Pr...

Page 16: ...r Codes with User Options for each code Refer to the tables below for available data entries for User Options Press w once to set cursor to the User Number and enter the desired User Number Press w on...

Page 17: ...0 for Blank Space 2 For User Options press 0 for Blank Space 28 INTERIOR BYPASS FIRE TBL SYS TBL CHIME INTERIOR BYPASS FIRE TBL SYS TBL CHIME Quick Enroll Method If a receiver is already installed in...

Page 18: ...a maximum of 64 controlled zones can be assigned providing multiple wireless panic buttons on a system each reporting to the Central Station or a pager and or annunciating on a keypad the key fob zone...

Page 19: ...to silence the keypad Direct Entry 33 INTERIOR BYPASS FIRE TBL SYS TBL CHIME INTERIOR BYPASS FIRE TBL SYS TBL CHIME rE ZONE DESCRIPTIONS GEM DXK3 or GEM DXRP3 cannot be used to enter Zone Description...

Page 20: ...de is more flexible allowing you to change all the options It consists of multiple address locations with two data entry locations each left and right as shown in the adjacent diagram LEFT DIGIT RIGHT...

Page 21: ...BL CHIME FIRE TBL 1 2 Flashing GEM DXRP3 GEM DXK3 Keypads Press w followed by 1 the 4 digit address location and 2 the corresponding data shown Note A long beep sounds when in Address Program Mode 1 2...

Page 22: ...one of which are Exit Entry Follower Zones is entered as a blank PROGRAM THE DATA ENTRIES 1 Enter the panel s Dealer Security Code then press w 2 Answer NO X or q to all questions until ACTIVATE PROGR...

Page 23: ...ts on the left data display segment and the right digit on the right segment For those addresses having only one programmable nibble program the right segment only the left segment should display a bl...

Page 24: ...elected data entry in the boxes shown 4 For more information on a programming option refer to the Glossary at the end of this manual EXIT ADDRESS 0000 DELAY LEFT RIGHT sec Default 3 C ENTRY ADDRESS 00...

Page 25: ...MAT OPTIONS ADDRESS 0546 0547 LEADING DIGITS FOR PAGER FORMAT In Pager Format reporting the message typically begins with 00 However for some pager services this will cause the Pager s Voice Mail feat...

Page 26: ...0837 8 4 2 1 PGM1 Output 8 4 2 1 0838 8 4 2 1 PGM2 Output 8 4 2 1 0839 8 4 2 1 Report Event Telco 1 8 4 2 1 0840 8 4 2 1 Report Restore Telco 1 8 4 2 1 0841 8 4 2 1 Report Event Telco 3 8 4 2 1 0842...

Page 27: ...rm Output 8 4 2 1 0872 8 4 2 1 Alarm Output 8 4 2 1 0873 8 4 2 1 PGM1 Output 8 4 2 1 0874 8 4 2 1 PGM2 Output 8 4 2 1 0876 8 4 2 1 Report Event Telco 1 8 4 2 1 0877 8 4 2 1 Report Event Telco 3 8 4 2...

Page 28: ...reless Trouble Activates Telco 3 8 Enable Alarm Output on Telco Fail only when Armed RIGHT DATA VALUES CIRCLE SYSTEM OPTIONS 1 Automatic Interior Bypass Easy Exit RESERVED RESERVED 8 Resound on Wirele...

Page 29: ...circling the data values for each digit left and right 2 Add the data values ex F 15 1 2 4 8 from the selected options See page 23 3 Enter in address location left and right digits NOTE Dark shaded da...

Page 30: ...Question CENTRAL PHONE Default blank across digits 1 20 for CS Receiver Telephone Numbers 2 and 3 CS Receiver 1 LEFT RIGHT Format blank ADDRESS 0460 CS Receiver 2 LEFT RIGHT Format blank ADDRESS 0482...

Page 31: ...S 1 4 0664 0665 0666 0667 CS Telco 1 Sub scriber Opening Closing ID Number Area 4 ADDRESS 0572 0575 RIGHT DIGITS 1 4 0572 0573 0574 0575 CS Telco 1 Sub scriber Opening Closing ID Number Area 3 ADDRESS...

Page 32: ...se 0704 Keyfob Low Battery 0705 CS SYSTEM REPORTING OPTIONS ADDRESS 0670 0705 CS AREA SYSTEM REPORTING OPTIONS ADDRESS 0785 0786 0788 Default blank blank LEFT DIGIT SUM RIGHT DIGIT SUM ADDRESS 0788 CS...

Page 33: ...desired delay timeout ex 20 sec B Divide it by 16 4 Press u to save EXIT ENTRY DELAYS Apply only to zones programmed with the following options Exit Entry 1 Exit Entry 2 Exit Entry Follower NOTE Senso...

Page 34: ...DDRESS 0740 0743 ZONES REPORT CODE ZONE 21 ZONE 22 ZONE 23 ZONE 24 0740 0741 0742 L R L R L R L R 0743 ZONE REPORT CODE OPTIONS LEFT RIGHT DATA ENTRIES NOTE If Zone Doubling Address 1423 is not enable...

Page 35: ...User 25 8 4 2 1 8 4 2 1 RIGHT DATA VALUES LEFT DATA VALUES ADDRESS 0804 User Opening Telco 1 User 40 User 39 User 38 User 37 LEFT RIGHT User 36 User 35 User 34 User 33 8 4 2 1 8 4 2 1 RIGHT DATA VALU...

Page 36: ...User 25 8 4 2 1 8 4 2 1 RIGHT DATA VALUES LEFT DATA VALUES ADDRESS 0822 User Opening Telco 3 User 40 User 39 User 38 User 37 LEFT RIGHT User 36 User 35 User 34 User 33 8 4 2 1 8 4 2 1 RIGHT DATA VALU...

Page 37: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 37 This page left blank intentionally...

Page 38: ...SERVED 1 RESERVED 2 RESERVED 4 RESERVED 8 Default blank one 1 Burglary Output Turns Off upon Disarm LEFT DIGIT SUM OF DATA VALUES RIGHT DIGIT SUM OF DATA VALUES 1 ADDRESS 1475 RIGHT DATA VALUES CIRCLE...

Page 39: ...RVED 1 RESERVED 2 RESERVED 4 RESERVED 8 Default blank one 1 Pulsed Burg Output Turns Off upon Disarm LEFT DIGIT SUM OF DATA VALUES RIGHT DIGIT SUM OF DATA VALUES 1 ADDRESS 1479 RIGHT DATA VALUES Disar...

Page 40: ...ESERVED 1 RESERVED 2 RESERVED 4 RESERVED 8 Default blank one 1 PGM1 Output Turns Off upon Disarm LEFT DIGIT SUM OF DATA VALUES RIGHT DIGIT SUM OF DATA VALUES 1 ADDRESS 1483 RIGHT DATA VALUES CIRCLE Di...

Page 41: ...ESERVED 1 RESERVED 2 RESERVED 4 RESERVED 8 Default blank one 1 PGM2 Output Turns Off upon Disarm LEFT DIGIT SUM OF DATA VALUES RIGHT DIGIT SUM OF DATA VALUES 1 ADDRESS 1487 RIGHT DATA VALUES Disarming...

Page 42: ...dress locations above 3 Press u to save KEYPAD OPTIONS ADDRESS 1425 1431 1440 1446 RIGHT OPTION blank Disabled 1 Active Keypad KEYPAD ASSIGNMENT KEYPAD NO KEYPAD OPTIONS LEFT DATA VALUES CIRCLE ADDRES...

Page 43: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 43 This page left blank intentionally...

Page 44: ...is 255 If a value above 255 is entered the system will display 000 to request a re entry Note Only the panel zones integration times are programmable In addition zone re sponses are enabled only when...

Page 45: ...8 4 2 1 8 4 2 1 0933 8 4 2 1 Trouble on Open 8 4 2 1 0998 8 4 2 1 8 4 2 1 0934 8 4 2 1 Trouble on Short 8 4 2 1 0999 8 4 2 1 8 4 2 1 0935 8 4 2 1 Zone Area 1 8 4 2 1 1000 8 4 2 1 8 4 2 1 0936 8 4 2 1...

Page 46: ...down 8 4 2 1 1110 8 4 2 1 8 4 2 1 1046 8 4 2 1 Chime 8 4 2 1 1111 8 4 2 1 8 4 2 1 1047 8 4 2 1 Abort Delay 8 4 2 1 1112 8 4 2 1 8 4 2 1 1048 8 4 2 1 Power up Delay 8 4 2 1 1113 8 4 2 1 8 4 2 1 1049 8...

Page 47: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 47 This page left blank intentionally...

Page 48: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 48 This page left blank intentionally...

Page 49: ...ent ID COND ADDRESS 1544 1548 RELAY EVENT 12 1544 1545 1546 1547 L R L R L R L R L R 1548 RELAY AREA Timeout Event ID COND ADDRESS 1549 1553 RELAY EVENT 13 1549 1550 1551 1552 L R L R L R L R L R 1553...

Page 50: ...address locations left and right digit STEP 5 RELAY EVENT CONDITION OPTIONS Each relay event can be assigned an alarm type and an activation condition also select a timeout type for each 5A Select Al...

Page 51: ...General System Alarm D 8 Area 1 General System Alarm D 9 Area 2 General System Alarm D 0 Area 3 General System Alarm D B Area 4 General System Alarm F blank Relay Control Group 1 F 1 Relay Control Gr...

Page 52: ...Press u to save NOTE These timers apply only to Supervised RF Transmitters see RF Transmitters in Easy Menu Driven Mode Programming Default blank blank from address 2029 2044 RF SUPERVISORY TIMER RF...

Page 53: ...Software If power fails time and date restarts at 00 00 00 and a date of 01 01 04 January 1 2004 GEM DXRP1 Keypad 2286 XX GEM DXRP2 Keypad 2286 XX USER PROGRAM MODE PRELIMINARY INFORMATION The User Pr...

Page 54: ...igit User Number 01 64 directly using number buttons 0 9 2 Press the w button 3 Enter Code 1 6 digits directly using number buttons 0 9 4 Press the u button to save each code NOTE Press G 0 button to...

Page 55: ...DXK3 and GEM DXK4RF Keypads Up to 7 GEM DXRP2 GEM DXK2 GEM DXRP3 GEM DXK3 and or GEM DXK4RF keypads may be connected to the panel Keypads 1 7 Each must be configured for a keypad address In addition...

Page 56: ...PROGRAM MENU 10 AUTO BELL TEST ON ARMING ADDRESS 1421 28 AUTO BYPASS RE ENTRY ZONES EASY PROGRAM MENU 8 14 15 AUTO RESET AFTER BURGLARY OUTPUT TIMEOUT ADDRESS 1421 28 AUTO RESET ZONE OPTION 45 46 47...

Page 57: ...CROLLING ADDRESS 1420 28 DON T CLEAR PGM2 OUTPUT WITH DISARM ADDRESS 1424 28 DOWNLOAD CALLBACK OPTIONS ADDRESS 2059 0526 0545 25 DOWNLOADING FROM A COMPUTER 4 E EASY ARMING KEYPAD OPTIONS 42 EASY MENU...

Page 58: ...ONS 42 KEYPAD INSTALLATION 55 KEYPAD OPTIONS ADDRESS 1425 1431 1440 1446 42 KEYPAD PANIC 26 27 KEYPAD PANIC KEYPAD OPTIONS 42 KEYPAD PROGRAMMING OVERVIEW 20 KEYPAD SOUNDER ON ALARM ZONES EASY PROGRAM...

Page 59: ...ORT EVENT TELCO 1 ADDRESS 0869 26 27 REPORT EVENT TELCO 1 ADDRESS 0877 27 REPORT EVENT TELCO 3 ADDRESS 0842 26 REPORT EVENT TELCO 3 ADDRESS 0863 26 REPORT EVENT TELCO 3 ADDRESS 0871 26 27 REPORT OPTIO...

Page 60: ...OPTIONS 17 USER PROGRAM MODE 4 USER PROGRAM MODE 53 V VERTEX RECEIVER FORMAT 16 W WIRELESS TROUBLE ACTIVATES TELCO 1 ADDRESS 1423 28 WIRELESS TROUBLE ACTIVATES TELCO 3 ADDRESS 1423 28 WIRING DIAGRAM 6...

Page 61: ...AFTER ALARM REPORTING OPTIONS 32 ADDRESS 0680 CONDITIONAL CLOSE REPORTING OPTIONS 32 ADDRESS 0681 CANCEL REPORTING OPTIONS 32 ADDRESS 0682 TEST TIMER REPORTING OPTIONS 32 ADDRESS 0683 TELCO FAIL REPO...

Page 62: ...CLOSE STATUS 28 ADDRESS 1420 OPENING REPORT ONLY AFTER ALARM REPORT 28 ADDRESS 1420 STATUS REPORT 28 ADDRESS 1421 ACCESS CONTROL ON PGM2 OUTPUT 28 ADDRESS 1421 AUTO BELL TEST ON ARMING 28 ADDRESS 1421...

Page 63: ...3 DISABLE CALL WAITING ON 1ST ATTEMPT 29 ADDRESS 2053 ENABLE CP 01 EGRESS TONES ONLY 29 ADDRESS 2053 ENABLE CP 01 LIMITS 29 ADDRESS 2053 ENABLE KEYPAD 1 ONLY PROGRAMMING 29 ADDRESS 2053 EXIT TIME REST...

Page 64: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 64 LIB P432EX WIRING DIAGRAM...

Page 65: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 65 LIB P432EXT WIRING DIAGRAM...

Page 66: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 66 LIB P432EXT 230 WIRING DIAGRAM...

Page 67: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 67 NOTES...

Page 68: ...68 R Publicly traded on NASDAQ Symbol NSSC NAPCO Security Group Inc 333 Bayview Avenue Amityville New York 11701 For Sales and Repairs call toll free 800 645 9445 For direct line to Technical Service...

Reviews: