LIBRA LIB-P432EX Series Programming Instructions
NAPCO Security Systems
Page 34
Default for Group Zone Report Codes depends on Easy Menu Question “RCVR. FORMAT”.
CS ZONE REPORTING OPTIONS (ADDRESS 0720-0751)
ADDRESS 0720-0727
CONTROL PANEL ZONES REPORT CODE
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8
0720
0721
0722
0723
0724
0725
0726
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
0727
ADDRESS 0728-0731
ZONES REPORT CODE
ZONE 9 ZONE 10 ZONE 11 ZONE 12
0728
0729
0730
L
R
L
R
L
R
L
R
0731
ADDRESS 0732-0735
ZONES REPORT CODE
ZONE 13 ZONE 14 ZONE 15 ZONE 16
0732
0733
0734
L
R
L
R
L
R
L
R
0735
ADDRESS 0744-0747
ZONES REPORT CODE
ZONE 25 ZONE 26 ZONE 27 ZONE 28
0744
0745
0746
L
R
L
R
L
R
L
R
0747
ADDRESS 0748-0751
ZONES REPORT CODE
ZONE 29 ZONE 30 ZONE 31 ZONE 32
0748
0749
0750
L
R
L
R
L
R
L
R
0751
ADDRESS 0736-0739
ZONES REPORT CODE
ZONE 17 ZONE 18 ZONE 19 ZONE 20
0736
0737
0738
L
R
L
R
L
R
L
R
0739
ADDRESS 0740-0743
ZONES REPORT CODE
ZONE 21 ZONE 22 ZONE 23 ZONE 24
0740
0741
0742
L
R
L
R
L
R
L
R
0743
ZONE REPORT
CODE OPTIONS
LEFT
RIGHT
DATA ENTRIES
NOTE:
If "Zone Doubling" (Address 1423) is not enabled, then Zones 1-4 are included in the control panel and Zones
5-32 are wireless Zones. If "Zone Doubling" is enabled, then Zones 1-4 and 9-12 are included in the control panel;
Zones 5 through 32 are available as wireless--however--Zones 9-12 would be ORed with the hardwired zones.
PULSE EVENT CODE
will be the first digit of the 2 digit reporting code. The second digit will be the
second digit of the reporting zone. For example, for zone 9 (address 0728), if the right digit is “3", then
the reporting code is ”39". For example, for zone 15 (address 0734), if the right digit is “4", then the re-
porting code is ”45".
MODEM CODES
determine the zone types reported for the following formats: SIA and ADEMCO Point ID.
1. Select the desired Modem Code for each zone from the table shown.
2. Press
u
to save.
DATA
ENTRIES
MODEM CODE
LEFT
1
Fire
2
Panic
3
Burglary
4
Hold up
7
Gas Alarm
8
Heat Alarm
0
Auxiliary Alarm
B
24 Hour Auxiliary