LIBRA LIB-P432EX Series Programming Instructions
NAPCO Security Systems
Page 44
AREA ARMING OPTIONS (ADDRESS 1469-1472)
PRIORITY AREA ARMING:
1. Select option from the table shown.
2. Enter in corresponding right digit address location (left digit is not used).
NOTE:
Dark shaded data value box shows option not available.
3. Press
u
to save.
PRIORITY ARMING/AREA 1
OPTION
LEFT
RIGHT
blank (•)
blank (•) Not Used
blank (•)
1
Enabled
DATA ENTRIES
PRIORITY ARMING/AREA 2
OPTION
LEFT
RIGHT
blank (•)
blank (•) Not Used
blank (•)
1
Enabled
DATA ENTRIES
Priority
ADDRESS 1469
Arming
LEFT
RIGHT
Area 1
blank (•)
[Default = blank (•) blank (•)]
Priority
ADDRESS 1470
Arming
LEFT
RIGHT
Area 2
blank (•)
[Default = blank (•) blank (•)]
ZONE INTEGRATION TIME (ADDRESS 2062)
Zone Integration Time:
The panel Zone Integration (Response) time can be adjusted to a
new global value. Address 2062 accepts three decimal digits which are multiplied by 10 milli-
seconds to get a new value that replaces the default value of 750ms. If the location is set to
000, the system will default to 750ms internally. The maximum value is 255. If a value above
255 is entered the system will display 000 to request a re-entry.
Note:
Only the panel zones’ integration times are programmable. In addition, zone re-
sponses are enabled only when armed.
PRIORITY ARMING/AREA 1
OPTION
LEFT
RIGHT
blank (•)
blank (•) Not Used
blank (•)
1
Enabled
DATA ENTRIES
PRIORITY ARMING/AREA 2
OPTION
LEFT
RIGHT
blank (•)
blank (•) Not Used
blank (•)
1
Enabled
DATA ENTRIES
Priority
ADDRESS 1471
Arming
LEFT
RIGHT
Area 3
blank (•)
[Default = blank (•) blank (•)]
Priority
ADDRESS 1472
Arming
LEFT
RIGHT
Area 4
blank (•)
[Default = blank (•) blank (•)]
ADDRESS 2280
LEFT
RIGHT
[Default = 075 x 10ms = 750ms]
Zone
Integration
Time (x 10ms)
ZONE INTEGRATION TIME
TIMEOUT
LEFT
RIGHT
blank (•)
blank (•)
(0) 1/100 sec. = 0 will
default to 750ms.
blank (•)
2
(2) 1/100 sec. = 20ms.
blank (•)
3
(3) 1/100 sec. = 30ms.
blank (•)
4
(4) 1/100 sec. = 40ms.
blank (•)
5
(5) 1/100 sec. = 50ms.
blank (•)
6
(6) 1/100 sec. = 60ms.
blank (•)
7
(7) 1/100 sec. = 70ms.
blank (•)
8
(8) 1/100 sec. = 80ms.
F
F
(255) 1/100 sec. = 2.55
sec.
DATA ENTRIES
1. Select delay/timeout from the table shown at left.
2. Enter in corresponding address locations above (left and right digits).
3. For a desired delay/timeout not listed do the following:
A. Choose a desired delay/timeout, ex: 20
B. Divide it by 16
4. Press
u
to save.
1 Quotient Left Digit
16 20
16
4 Remainder Right Digit