KEYPAD CONFIGURATION MODE
Press
A
button
Enter Factory Code:
11123
Configure:
•
Keypad Beep ON/OFF
•
Entry Sounder
•
Keypad Address 01
•
New Compat# 0000 **
•
EZM Address 00
•
Zone Response 00
•
Program Control Message# 1
Press
C
button
(“
01 OUT OF SYSTEM
”)
Return Jumper JP5 * from Pins 2-3 to Pins 1-2
(“
SYSTEM READY
”)
Move Jumper JP5 * from Pins 1-2 to Pins 2-3
(Wait about 15 seconds: “
01 OUT OF SYSTEM
”)
* JP5 is located at the top-right corner of the circuit board.
** If a Compatibility Number other than “0000” is programmed, “
OLD COMPAT# XXXX
” is displayed.
KEYP
A
D
PROGR
A
M
M
ING MODES
GEM-RP1CAe2/GEM-K1CA
KEYPADS
Configure:
•
Keypad Address (Jumpers J1-J3)
•
TouchPad Backlight (Jumper A)
•
LCD Backlight (Jumper B)
•
Entry Sounder (Jumper C)
GEM-RP2ASe2
KEYPADS
1 2
4
3
5 6
7 8 9 0
A
B
C
D
E
F
G
NEXT/YES
PRIOR/NO
AREA
Scroll Down
Scroll Up
Exit
Yes
No
R
For "K Series" Keypads
Save
Scroll
1 2
4
3
5 6
7 8 9 0
A
B
C
D
E
F
G
NEXT/YES
PRIOR/NO
AREA
Scroll Down
Scroll Up
Exit
Yes
No
For "Classic" Keypads
Save
Scroll