WI850D GEM-P800 Installation Instructions
8
Keypad LED's
ARMED
LED
DEFINITION
Armed ............................................................ON
Instant Mode .................................... Rapid Flash
Zone in Alarm ........................................Flashing
STATUS
LED
DEFINITION
Ready to be Armed ........................................ON
Zone faulted ................................................. OFF
H
TROUBLE
LED
DEFINITION
AC Failure ..............................................Flashing
System Trouble(s) ........................................ON
I
FIRE
LED
DEFINITION
Fire Alarm ..............................................Flashing
Fire Memory / *Fire Trbl .................................ON
*See Note 1
AC
LED
DEFINITION
AC Present ....................................................ON
AC Failure ................................................... OFF
ZONE
LED
DEFINITION
Faulted Zone ..................................................ON
Bypassed Zone .................................Slow Flash
Zone in Alarm ........................................Flashing
Panel Operation
Arming (System ON)
Before arming the system close all protected
zones (unless programmed as Auto-Bypass
Reentry Zones). Enter a 4-digit Arm/Disarm
code, followed by the
D
key, the keypad will
provide a feedback beep for each key pressed.
If a valid Arm/Disarm code is entered, the key-
pad will beep 3 times. If an incorrect Arm/
Disarm code is entered, the keypad will sound a
1-second tone indicating an incorrect entry.
Arming without Entry Delay (Instant
Mode)
Enter the
F
key to eliminate the entry delay.
The ARMED LED will flash rapidly to indicate
the panel is in Instant Mode. If an Exit/Entry
Zone is tripped while the panel is in Instant
Mode the panel will go into alarm immediately.
Arming/Disarming with a Keyfob
The system can be armed by pressing the
K
key, and disarmed by pressing the
L
key on
the Keyfob. Zones programmed as
Exit/Entry
Follower Zones
can be bypassed when the
M
or
N
keys on the Keyfob have been pro-
grammed for
Interior
[81-84]. Zones pro-
grammed as Home
/Away with Delay Zones
can
be armed regardless of the state of the
Exit/
Entry Zones
when the
M
or
N
keys on the
Keyfob have been programmed for
Full Set
[81-
84]. To arm the system with all zones protected
press the
K
key. Press and hold the
M
or
N
key for 1.5s to fully set the system (the LED
on the Keyfob indicate the Keyfob has transmit-
ted the signal). Program
Keyfob/Keyswitch Chirp
[23-4] for an audible indication of system arming
and disarming.
Arming/Disarming with a Keyswitch
The system can be armed/disarmed by using a
momentary Keyswitch wired to
Zone 6
.
Pro-
gram Keyfob/Keyswitch Chirp
[23-4] for an audi-
ble indication of system arming and disarming.
Arming Instant with a Keyfob
The panel can be ARMED INSTANT when the
M
or
N
keys on the Keyfob have been pro-
grammed for
Instant
[81-84]. To arm the sys-
tem with Instant protection press the
K
key,
then press and hold the
M
or
N
key for 1.5s
to arm the panel with INSTANT protection.
Disarming (System OFF)
After entering the premises through an Exit/
Entry Zone, the keypad will sound the Entry De-
lay Tone. Enter a valid Arm/Disarm code, then
* If
Fire Trouble on Fire LED
[96-4] has been enabled, a steady
Fire LED will indicate Fire Trouble.
N
OTE
:
Faulted Keyswitch or silent 24 hour zone normally do not
display at the keypad. If a silent 24 hour zone or Keyswitch
is faulted at the time of arming the faulted zone will display
only while the priority sound is ON.
N
OTE
: