8
Troubleshooting Procedures (Cont.)
Problem
Procedure
10.Excessive loss of water
noticed after normal cycle.
1. Vessel not filled to proper water level at beginning of cycle.
2. Steam leak at door gasket.
3. Steam leak at copper tubing connections; See Section 15.
4. Debris on solenoid valve seat causing leak; See Section 10.
5. Several or extended power interruptions.
6. See Problems #7 & #9.
7. Safety pressure relief valve seat leaking; See Section 15.
1. Dryer Element open; See Section 13.
11.Drying element does not
heat, Dryer Light 'ON', Timer
Light 'ON'
12.Drying element does not
heat, Dryer Light 'OFF', Timer
Light 'ON'.
1. Function switch in wrong position or faulty; See Section 6.
2. Dryer temperature Control faulty; See Section 14.
13.Timer does not function
properly
14.Unit runs out of water or fails
to shut off at excessive
temperature resulting heat
damage.
1. Low Water Cut-Off Switch failure; See Section 5.
1. Timer; See Section 1.