Steam Pipe
Valve
Packing
Mesh-filter
Drain Pipe
Steam Supply Hose
Valve
Check Valve
Steam Trap
Packing
Drain Pipe
CAUTION
• Please do not mistake the drain joint for
the steam supply joint.
• When fastening or unfastening the cap
nut of the Extra-Hose with a spanner, be sure to
hold the hex-part of hose joint on the iron firmly
with another spanner.
CAUTION
Failure to use the mesh-filter will cause
suction of dust and impurities into the
iron together with steam which may give
rise to malfunctions and problems with the iron.
WARNING
The iron reaches a high temperature after
the steaming, so be sure to place it on
the iron-rest, and never place it directly
on the ironing table or by the flammables.
Insert the other end of the inner tube into the
mouth piece (G1/4) of the steam supply hose.
Screw the cap but of the hose to the joint of
the iron and fix it.
- Installation of the Drain Hose
Connect the mouth piece (G1/4) of the drain
hose to the drain hose joint of the iron and fix it.
- Connection of the steam supply hose to a
steam boiler or a central piping system
Connect the end of the steam supply hose to
the steam intake of the boiler.
Before screwing in the nut, be sure to place the
supplied mesh-filter and packing in the steam
intake of the boiler.
Connect the end of the drain supply hose to the
drain intake of the boiler. If a NAOMOTO
NBC-series light-type boiler is used, be sure to
place a gasket (black color) and mesh-filter in
the condensate return inlet of the boiler before
connecting the return hose to it. They are
available as option.
- Place the Iron
Please see that the iron is placed on the
supplied iron-rest when not in use.
The following drawing is an example to connect
to central piping system:
Extra - Hose
Mesh Filter &
Packing ser
Steam Inlet
Condensate Return
Inlet
NAOMOTO NBC Boiler
NAOMOTO NBC Boiler