CAUTION
Be sure to set the drain valve to be
opened fully (c) to use a condensate
return device or a steam trap
6. IRONING OPERATION
When starting and finishing operation, follow
the instructions below. To ensure the correct
operation of the iron, read also the instruction
manual of the boiler, which is to be used with
the iron
6.1 General Advise
- Check the pressure of the boiler by its
pressure gauge and open the steam valve
of the boiler.
- Adjustment of the iron drain valve.
This valve is not completely closed, so there is
clearance with condition of above (c), draining
is possible
(a) Full Open
0.1 MPa
(b) Half Open
0.2 MPa
(c) Closed
More than 0.3 MPa
6.2 Start of Operation
Push the push lever to start steam. At first,
water drops may come out with steam, good
steam comes out in a minute with the
condition of appropriate draining.
CAUTION
Sole plate temperature of all steam iron
as this product is controlled by the steam
pressure of the boiler. Refer to the table
shown below, and check the steam pressure.
However, this table is reference materials, so, the
value on the table are not guaranteed.
Steam
Pressure (MPa)
0.1
0.2
0.3
0.4
0.5
Steam
Temp. (°C)
120
133
143
151
158
Sole Plate
Temp. (°C)
113
125
135
142
149
6.3 At the End of Daily Operation
- Close the steam valve of the boiler.
- Open draining valve fully, then keep the lever
pushing down until all the remaining steam
and water inside the iron and hose have
been blown out.
To start new operation, begin it according to
the START instructions.