Page 9
5. SERVICE ‘A’ INSTRUCTIONS - Silencers/Mufflers
(Every year or 6,000 hours)
REPLACE EXTERNAL EXHAUST SILENCERS/MUFFLERS
1. Ensure the dryer is shut down and fully depressurised.
See Page 8, section 4.1.
2. Remove Exhaust Silencer/Mufflers from the unit and
discard (figure A.1)
3. Clean the thread and remove any sealing material debris
from external exhaust elbow (figure A.3)
4. Apply new thread sealing material to new Exhaust
Silencer/Mufflers, shown in figure A.4
5. Attach Exhaust Silencer/Mufflers, ensuring they are tight.
Figure A.1
Figure A.2
Figure A.3
Remove all debris
Figure A.4
Apply new thread sealing
material